Publication:
Application of Sentinel Node Biopsy in Breast Cancer Patients with Clinically Negative and Positive Axilla and Role of Axillary Ultrasound Examination to Select Patients for Sentinel Node Biopsy

dc.contributor.authorKuru, B.
dc.contributor.authorGulcelik, M. Ali
dc.contributor.authorTopgul, K.
dc.contributor.authorOzaslan, C.
dc.contributor.authorDinc, S.
dc.contributor.authorDincer, H.
dc.contributor.authorAlagol, H.
dc.contributor.authorIDOzaslan, Cihangir/0000-0002-2611-4837
dc.contributor.authorIDKuru, Bekir/0000-0001-7774-6431
dc.date.accessioned2020-06-21T14:39:52Z
dc.date.available2020-06-21T14:39:52Z
dc.date.issued2011
dc.departmentOMÜen_US
dc.department-temp[Kuru, B.] Ondokuz Mayis Univ, Genel Cerrahi AD, Sch Med, Dept Surg, TR-55139 Kurupelit, Samsun, Turkey -- [Gulcelik, M. Ali -- Ozaslan, C. -- Dincer, H. -- Bozgul, M. -- Camlibel, M.] Ankara Oncol Educ & Res Hosp, Dept Surg, Ankara, Turkey -- [Dinc, S.] Ankara Educ & Res Hosp, Dept Surg, Ankara, Turkeyen_US
dc.description.abstractPurpose: To evaluate the identification rate and the false-negative (FN) rate of sentinel lymph node biopsy (SLNB) using preoperative axillary ultrasound (AU) in patients with clinically negative and positive axilla and to prove that SLNB could also be performed in clinically axillary positive patients. Methods: Three hundred and fifty seven consecutive T1-2 invasive breast cancer patients with clinically negative or positive axilla were enrolled in our Institution between 2006 and 2011. All patients had preoperative AU, and underwent SLNB followed by breast conserving surgery or mastectomy with level 1, 2 axillary dissection. SLNB was performed using 5 mL of 1% methylene blue. The identification (ID) rate and the FN rate of SLNB were calculated for patients with clinically negative and positive axilla, and for patients with negative AU. Results: Two hundred thirty two patients (65%) were clinically axillary-negative and 125 (35%) were clinically axillary-positive. The ID rates of SLNB were 91 and 89% and the FN rates were 7 and 9%, respectively, in patients with clinically negative and positive axilla. The ID rate of SLNB increased to 94% and the FN rate decreased to 4% after the exclusion of 85 patients (24%) with metastatic lymph nodes on AU. Conclusion: SLNB can be safely applied to T1 tumors regardless of the clinical status of the axilla. Use of AU before SLNB significantly increases the ID rate and decreases the FN rate of SLNB in clinically axillary negative as well as in positive patients.en_US
dc.identifier.endpage459en_US
dc.identifier.issn1107-0625
dc.identifier.issue3en_US
dc.identifier.pmid22006749
dc.identifier.startpage454en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/17116
dc.identifier.volume16en_US
dc.identifier.wosWOS:000295563900011
dc.language.isoenen_US
dc.publisherZerbinis Medical Publen_US
dc.relation.journalJournal of Buonen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAxillary Ultrasounden_US
dc.subjectClinically Negative Axillaen_US
dc.subjectClinically Positive Axillaen_US
dc.subjectInvasive Breast Canceren_US
dc.subjectMethylene Blueen_US
dc.subjectSentinel Lymph Node Biopsyen_US
dc.titleApplication of Sentinel Node Biopsy in Breast Cancer Patients with Clinically Negative and Positive Axilla and Role of Axillary Ultrasound Examination to Select Patients for Sentinel Node Biopsyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files