Publication:
Tiroid Nodüllerinin Benign-malign Ayrımında Sonoelastografinin Tanısal Değeri

dc.contributor.advisorElmalı, Muzaffer
dc.contributor.authorAydın, Ramazan
dc.date.accessioned2020-07-22T10:19:19Z
dc.date.available2020-07-22T10:19:19Z
dc.date.issued2013
dc.departmentOMÜ, Tıp Fakültesi, Radyodiagnostik Anabilim Dalıen_US
dc.departmentTıp Fakültesi / Radyodiagnostik Ana Bilim Dalı
dc.descriptionTez (tıpta uzmanlık) -- Ondokuz Mayıs Üniversitesi, 2013en_US
dc.descriptionLibra Kayıt No: 69689en_US
dc.description.abstractAmaç: Bu çalışmanın amacı benign ve malign tiroid nodülü ayrımında ultrasonografinin (US), renkli Doppler ultrasonografinin (RDUS), sonoelastografinin, kas-nodül gerinim oranının (KNGO) tanısal değerini ve KNGO ile parankim-nodül gerinim oranı (PNGO) arasında tanısal açıdan fark olup olmadığını araştırmaktır.Gereç ve Yöntem: Çalışma fakülte etik kurulu tarafından onaylandı ve tüm hastalardan yazılı onam alındı. Tiroidde nodülü bulunan ve ince aspirasyon biyopsi (İİAB) işlemi için gönderilen 106 ardışık hastaya (88 K, 18 E; 49±12 yaş) İİAB işleminden önce US, RDUS ve sonoelastografi yapıldı. Her bir nodülün US, RDUS ve sonoelastografi özellikleri kaydedildi. Sonoelastografide ortalama KNGO ve PNGO hesaplandı ve her iki gerinim oranı için ROC analizi kullanılarak benign ve malign nodül ayrımında eşik değer belirlendi. İki gerinim oranı arasındaki uyum k istatistiği ile değerlendirildi.Sonuçlar: Histopatolojik incelemeye göre nodüllerin 83'ü benign 23'ü malign olarak sonuçlandı. 4 kategoriden oluşan skorlamaya göre 83 benign nodülün 44'ü skor 1 veya 2'ye sahipken 23 malign nodülün 22'si skor 3 veya 4'e sahipti (AUC, 0.79; p<0.001). ROC analizinde benign ve malign nodül ayrımında eşik değer KNGO için 1.85, PNGO için 3.14 olarak hesaplandı (AUC, 0.98; p<0.001). KNGO için eşik değer 1.85 kullanıldığında; doğruluk, özgüllük, PPD, NPD ve doğruluk oranları sırasıyla % 95.6, % 92.8, % 78.6, % 98.7, % 93.4 ve PNGO için eşik değer 3.14 kullanıldığında ise sırasıyla % 95.6, % 84.0, % 81.5, % 98.7, % 94.3 olarak bulundu. KNGO ve PNGO için k değeri 0.87 olup mükemmele yakın uyumu göstermekteydi.Tartışma: Çalışmamızın sonucunda sonoelastografinin tiroid nodüllerinin benign ve malign ayrımında US ve RDUS ile karşılaştırıldığında daha yüksek tanısal değere sahip olduğu bulduk. Benign ve malign tiroid nodülü ayrımında KNGO için eşik değeri 1.85, PNGO için ise eşik değeri 3.14 olarak bulduk. Benign ve malign tiroid nodülü ayrımında KNGO ve PNGO arasında anlamlı fark yoktu. Sonuçta PNGO'nın kullanılamayacağı durumlarda KNGO'nın güvenle kullanılabileceğini düşünmekteyiz.Anahtar sözcükler: sonoelastografi, tiroid nodülü, ultrasonografi, gerinimi oranı, renkli Doppler ultrasonografi
dc.description.abstractPurpose: The aim of this study is to investigate the diagnostic value of ultrasonography (US), color Doppler ultrasound (CDU), sonoelastography (SE), muscle-to-nodule strain ratio (MNSR) in the differentiation of benign and malignant thyroid nodules and to see if there was a difference between MNSR and parenchyma-to-nodule strain ratios (PNSR) in diagnosis.Methods and Materials: The study was approved by the institutional ethics committee. Informed consent was obtained from all patients. A total of 106 consecutive patients (88 female and 18 male; mean [±SD] age, 49±12 years) with thyroid nodules who were referred for fine-needle aspiration biopsy (FNAB), were prospectively examined using US, CDU, and sonoelastography before the FNAB. The US, CDU, and SE features of each nodule were recorded. The mean MNSR and PNSR were calculated for each nodule and receiver operating characteristic (ROC) curve analysis was used to determine the best cutoff point for both strain ratios in the differentiation of benign and malignant thyroid nodules. The agreement between the two strain ratios was assessed using the weighted ? test statistic.Results: According to the histopathologic results, 83 of the nodules were benign and 23 were malignant. According to the four-point scoring system, 44 (53%) of the 83 benign nodules had a score of one or two while 22 (95%) of the 23 malignant nodules had a score of three or four. Using ROC analysis, the best cutoff point for MNSR 1.85 and for PNSR 3.14 was computed in the differentiation of benign and malignant thyroid nodules. The sensitivity, specificity, PPV, NPV, and accuracy rates for the MNSR were 95.6%, 92.8%, 78.6%, 98.7%, and 93.4%, respectively when the best cutoff points were used (p<0.001). For the PNSR, the sensitivity, specificity, PPV, NPV, and accuracy rates were 95.6%, 93.4%, 81.5%, 98.7%, and 94.3%, respectively. The ? value for the PNSR and MNSR methods was 0.87, which indicated an almost perfect agreement (p<0.001).Conclusion: As a result of our study, we found that sonoelastography had a higher diagnostic value in the differentiation of benign and malignant thyroid nodules as compared with US and CDU. We found the best cutoff point for MNSR 1.85 and 3.14 for PNSR in the differentiation of benign and malignant thyroid nodules. There was no significant difference between MNSR and PNSR in the differentiation of benign and malignant thyroid nodules. Consequently, we think that MNSR could safely be used in situations where PNSR could not be used.Key words: sonoelastography, thyroid nodule, ultrasonography, strain ratio, color Doppler ultrasonographyen_US
dc.formatX, 86 y. : şekil ; 30 smen_US
dc.identifier.endpage96
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=rcbWnuqW6HxCZ_98ARapggBuWiYaiaWzgCLqJTg1yjVtGYQub5IslppmrOQDaDNC
dc.identifier.urihttp://libra.omu.edu.tr/tezler/69689.pdf
dc.identifier.urihttps://hdl.handle.net/20.500.12712/32825
dc.identifier.yoktezid324155
dc.language.isotren_US
dc.publisherOndokuz Mayıs Üniversitesi, Tıp Fakultesien_US
dc.relation.publicationcategoryTezen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRadyoloji ve Nükleer Tıp
dc.subjectNeoplazmlar
dc.subjectNeoplazmlar
dc.subjectTeşhis-Ayırıcı
dc.subjectRadiology and Nuclear Medicineen_US
dc.subjectNeoplasmsen_US
dc.subjectTiroid Nodülleri
dc.subjectNeoplasmsen_US
dc.subjectDiagnosis-Differentialen_US
dc.subjectUltrasonografi
dc.subjectThyroid Noduleen_US
dc.subjectUltrasonographyen_US
dc.subjectUltrasonografi-Renkli Doppler
dc.subjectUltrasonography-Color Doppleren_US
dc.subject.otherTEZ TIP E371t 2013en_US
dc.titleTiroid Nodüllerinin Benign-malign Ayrımında Sonoelastografinin Tanısal Değeri
dc.titleThe Diagnostic Value of Sonoelastography in the Differentiation of Benign-Malignant Thyroid Nodulesen_US
dc.typeSpecialist Thesisen_US
dspace.entity.typePublication

Files