Publication:
Cyclic Fatigue Resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium Instruments

dc.authorscopusid56348812200
dc.contributor.authorOzyurek, T.
dc.date.accessioned2020-06-21T13:31:59Z
dc.date.available2020-06-21T13:31:59Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ozyurek] Taha, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractIntroduction The purpose of this study was to compare the cyclic fatigue resistance of Reciproc R25 (VDW, Munich, Germany), WaveOne Primary (Dentsply Maillefer, Ballaigues, Switzerland), and WaveOne Gold Primary files (Dentsply Maillefer). Methods Twenty Reciproc R25, 20 WaveOne Primary, and 20 WaveOne Gold Primary instruments were included in this study. The cyclic fatigue tests were performed using a cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. The files were randomly divided into 3 groups (group 1: Reciproc R25; group 2: WaveOne Primary; and group 3: WaveOne Gold Primary). All the instruments were rotated until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically (P < .05). Results There was a significant difference among the groups (P < .05). The WaveOne Gold Primary showed the greatest mean of NCF (1628 ± 107), and the WaveOne Primary showed the lowest mean of NCF (1153 ± 119.2). Conclusions Within the limitations of this in vitro study, the cyclic fatigue resistance of the WaveOne Gold Primary single-file system was higher than the WaveOne Primary and Reciproc R25 single-file instruments. © 2016 American Association of Endodontistsen_US
dc.identifier.doi10.1016/j.joen.2016.06.019
dc.identifier.endpage1539en_US
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.issue10en_US
dc.identifier.pmid27520406
dc.identifier.scopus2-s2.0-84990208165
dc.identifier.scopusqualityQ1
dc.identifier.startpage1536en_US
dc.identifier.urihttps://doi.org/10.1016/j.joen.2016.06.019
dc.identifier.volume42en_US
dc.identifier.wosWOS:000384781300020
dc.identifier.wosqualityQ1
dc.institutionauthorOzyurek, T.
dc.language.isoenen_US
dc.publisherElsevier Inc. usjcs@elsevier.comen_US
dc.relation.ispartofJournal of Endodonticsen_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCyclic Fatigue Resistanceen_US
dc.subjectEndodonticsen_US
dc.subjectReciprocen_US
dc.subjectStatic Modelen_US
dc.subjectWaveOne Golden_US
dc.titleCyclic Fatigue Resistance of Reciproc, WaveOne, and WaveOne Gold Nickel-Titanium Instrumentsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files