Publication:
Estimation of Online Transmission Line Parameters and Fault Location by Using Different Differential Equation Algorithms

dc.authorscopusid57188582201
dc.authorscopusid35791875600
dc.authorscopusid22433630600
dc.contributor.authorYıldız, D.
dc.contributor.authorKaragöl, S.
dc.contributor.authorÖzgönenel, O.
dc.date.accessioned2020-06-21T13:51:07Z
dc.date.available2020-06-21T13:51:07Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Yıldız] Doǧan, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Karagöl] Serap, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Özgönenel] Okan, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractDifferential Equation Algorithm (DEA), which is used as an alternative method to Fourier and similar algorithms, is among the online parameter estimation algorithms used in transmission line protection. Pi or T equivalent circuit parameters (R, L and C) of the transmission line can be calculated efficiently by using the fundamental harmonic components of voltage and current. DEA is a general model-based parameter estimation method and it does not depend on the form of the signal (voltage/current). Due to this feature DEA provides an efficient parameter estimation. In addition to traditional trapezoidal DEA algorithm, Simpson 1/3, Simpson 3/8, Simpson 7, Medium Point, Forward Euler, Backward Euler, Runge-Kutta and Boolean algorithms were first proposed in this study and the parameter estimations were performed on an exemplary transmission line. Thusly, it is proven that alternative methods can be used effectively on relays as an algorithm to find the location of a fault in the line. © 2015 Chamber of Electrical Engineers of Turkey.en_US
dc.identifier.doi10.1109/ELECO.2015.7394500
dc.identifier.endpage1038en_US
dc.identifier.isbn9786050107371
dc.identifier.scopus2-s2.0-84963865139
dc.identifier.startpage1034en_US
dc.identifier.urihttps://doi.org/10.1109/ELECO.2015.7394500
dc.identifier.wosWOS:000380410800181
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.relation.ispartof-- 9th International Conference on Electrical and Electronics Engineering, ELECO 2015 -- 2015-11-26 through 2015-11-28 -- Bursa -- 119202en_US
dc.relation.journal2015 9Th International Conference on Electrical and Electronics Engineering (Eleco)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEstimation of Online Transmission Line Parameters and Fault Location by Using Different Differential Equation Algorithmsen_US
dc.typeConference Objecten_US
dspace.entity.typePublication

Files