Publication:
Kardiyak Resenkronizasyon Tedavisine Yanıtsız Kalp Yetersizliği Hastalarına Noninvaziv Kardiyak Debi Cihazı ve Ekokardiyografik Yöntemle Yapılan Optimizasyonun Klinik Sonuçlarının Karşılaştırılması

dc.contributor.advisorYüksel, Serkan
dc.contributor.authorYenerçağ, Mustafa
dc.date.accessioned2020-07-22T10:14:25Z
dc.date.available2020-07-22T10:14:25Z
dc.date.issued2015
dc.departmentOMÜ, Tıp Fakültesi, Kardiyoloji Anabilim Dalıen_US
dc.departmentTıp Fakültesi / Kardiyoloji Ana Bilim Dalı
dc.descriptionTez (tıpta uzmanlık) -- Ondokuz Mayıs Üniversitesi, 2016en_US
dc.descriptionLibra Kayıt No: 87707en_US
dc.description.abstractGİRİŞ: Kardiyak resenkronizasyon tedavisi (KRT), kalp yetersizliği (KY) tedavisi için kullanılan cihaz bazlı tedavi yöntemidir. KRT' ye yeterli yanıt alınamayan olgularda KRT optimizasyonu olumlu etkiler sağlamaktadır. Bu çalışmamızda; KRT' ye yanıtsız kalp yetersizliği hastalarına ekokardiyografik ve NICOM bazlı yeni bir nonivaziv kardiyak debi ölçüm yöntemi ile yapılan optimizasyonun klinik sonuçlarını, ampirik pacemaker ayarları ile takip edilen hastalar ile karşılaştırmayı amaçladık. YÖNTEM:. Noninvaziv kardiyak debi ölçümü ile optimizasyon yapılan hastalar (NICOM grubu), ekokardiyografik yöntemlerle optimizasyon yapılan hastalar (EKO grubu) ve optimizasyon işlemi uygulanmayan ampirik ayarlar ile takip edilen hastalar ile 3 grup oluşturulup her gruba 25' er hasta alındı. Tüm hastaların işlem öncesinde demografik, klinik ve ekokardiyografik özellikleri değerlendirildi. Optimizasyon işleminden üç ay sonra hastaların klinik ve ekokardiyografik bulguları karşılaştırıldı. BULGULAR: Optimizasyon işlemi uygulanan hastaların %12' sinde optimal AV gecikme 120 msn, %60' ında ise optimal VV gecikme 0 msn olarak ayarlandı. NICOM grubundaki hastaların optimizasyon işleminden üç ay sonra değerlendirilen altı dakika yürüme mesafesinde ve SlVÇY-HZİ' de anlamlı artış, sol ventrikül sistol - diyastol sonu çap ve hacimlerinde anlamlı azalma izlendi. EKO grubundaki hastalarda ise altı dakika yürüme mesafesinde ve SlVÇY-HZİ anlamlı artış, NYHA sınıfı ve SPWMD, IVMD sürelerinde anlamlı düzelme izlendi. Tüm gruplar kendi aralarında karşılaştırıldıklarında kardiyak debi dışında klinik ve ekokardiyografik sonuçlarda anlamlı farklılık izlenmedi. SONUÇ: Bu çalışmada NICOM bazlı KRT optimizasyonu ekokardiyografik yöntem ile karşılaştırıldığında benzer klinik ve ekokardiyografik sonuçlar elde edilmiştir. NICOM bazlı optimizasyon, ekokardiyografik yönteme göre daha basit ve hızlı olup operatör bağımlı değildir. Ancak her iki optimizasyon metodunun klinik ve ekokardiyografik sonuçları ampirik ayarlardan daha üstün olarak saptanmadı. NICOM bazlı optimizasyon seçilmiş hastalarda ekokardiyografiye alternatif güvenilir bir optimizasyon yöntemi olarak kullanılabilir. Anahtar kelimeler: Kalp yetersizliği, Kardiyak debi, Kardiyak resenkronizasyon tedavisi, Optimizasyon
dc.description.abstractBACKGROUND: Cardiac resynchronization therapy (CRT), is a device-based therapy used to treat heart failure (HF). CRT optimization may provide positive effects in non-responder patients. In this study, we aimed to compare the clinical outcomes of optimization by echocardiographic and a new noninvasive NICOM- based method in patients. METHODS: Patients were divided into three groups according to optimization methods. In NICOM group patients, CRT devices were optimized by non-invasive measurement of cardiac output. CRT optimization is performed by echocardiographic based methods in ECHO group. In the empiric group default settings were preserved. Twenty-five patients were included in each group. Demographic, clinical and echocardiographic characteristics were evaluated all of the patients before the procedure. Clinical and echocardiographic findings of the patients were compared three months after the optimization process. RESULTS: We set the optimal AV delay 120 msn in 12 % of patients and optimal VV delay 0 msn in 60 % of patients. Six minutes walking distance and LVOT-VTI were increased and LV end-diastolic and end-systolic dimensions were decreased significantly in NICOM group after3 months. Six-minutes walking distance and LVOT-VTİ were increased, NYHA class and SPWMD and IVMD were improved significantly in the ECHO group patients. All groups compared and no significant difference in clinical and echocardiographic outcomes were found except the increased cardiac output in ECHO group. DISCUSSION: In this study, similar clinical and echocardiographic outcomes were obtained in the comparison of NICOM-based and echocardiographic optimization methods. NICOM-based optimization is simpler and faster than echocardiographic methods, and is not dependent on operator. However, both clinical and echocardiographic optimization methods were not found as superior to empirical settings. NICOM-based optimization can be used as a reliable alternative to echocardiographic optimization methods in selected patients. Key Words: Heart Failure, Cardiac Output, Cardiac Resynchronization Therapy, Optimizationen_US
dc.formatXV, 86 y. : şekil, tablo; 30 sm.en_US
dc.identifier.endpage101
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=WY5CM7tPNE2z_YM6pBu0t6rmSq_WDlUG0T-DUCMpcfFO2VL-HGUoZXNrQhz5Y5va
dc.identifier.urihttp://libra.omu.edu.tr/tezler/87707.pdf
dc.identifier.yoktezid417483
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Tıp Fakültesien_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKardiyoloji
dc.subjectEkokardiyografi
dc.subjectKalp Hastalıkları
dc.subjectKalp Yetmezliği
dc.subjectKardiyovasküler Hastalıklar
dc.subjectTedavi
dc.subjectCardiologyen_US
dc.subjectVentriküler Fonksiyon-Sol
dc.subjectEchocardiographyen_US
dc.subjectHeart Diseasesen_US
dc.subjectHeart Failureen_US
dc.subjectCardiovascular Diseasesen_US
dc.subjectTreatmenten_US
dc.subjectVentricular Function-Leften_US
dc.subject.otherTEZ TIP Y45k 2016en_US
dc.titleKardiyak Resenkronizasyon Tedavisine Yanıtsız Kalp Yetersizliği Hastalarına Noninvaziv Kardiyak Debi Cihazı ve Ekokardiyografik Yöntemle Yapılan Optimizasyonun Klinik Sonuçlarının Karşılaştırılması
dc.titleComparison of Clinical Outcomes After CRT Optimization by NICOM and Echocardiographic Methods in Nonresponder Heart Failure Patientsen_US
dc.typeSpecialist Thesisen_US
dspace.entity.typePublication

Files