Publication:
A Newly Developed Electrocatalytic Oxidation and Voltammetric Determination of Curcumin at the Surface of PdNP-Graphite Electrode by an Aqueous Solution Process With Al3+

dc.authorscopusid55774433600
dc.authorscopusid6603524165
dc.authorscopusid36642614000
dc.contributor.authorÇakir, S.
dc.contributor.authorBi̇Çer, E.
dc.contributor.authorArslan, E.Y.
dc.date.accessioned2020-06-21T13:46:02Z
dc.date.available2020-06-21T13:46:02Z
dc.date.issued2015
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Çakir] Semiha, Department of Chemistry, Gazi Üniversitesi, Ankara, Ankara, Turkey; [Bi̇Çer] Ender, Ondokuz Mayis University Faculty of Science and Arts, Samsun, Turkey; [Arslan] Emine Yilmaz, T.C. Sağlık Bakanlığı,, Ankara, Turkeyen_US
dc.description.abstractIn the first stage, the palladium nanoparticles (PdNps)-coated graphite electrode (PdNp/GE) has been prepared. Scanning electron microscopy (SEM) technique showed that the palladium nanoparticles were uniformly distributed with an average particle diameter of 60-75 nm. And then, a novel-modified electrode has been developed by the physical deposition of Al3+ ions on palladium nanoparticles (PdNps)-coated graphite electrode (Al3+/PdNp/GE). This modified electrode was characterized by square-wave voltammetry (SWV), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The sensitivities of PdNp/GE and Al3+/PdNp/GE electrodes were tested with dopamine. Al3+/PdNp/GE exhibited a catalytic activity for curcumin oxidation. The square-wave voltammogram of curcumin in phosphate buffer (pH = 2) gave an anodic peak at 0.56 V. The anodic peak current of curcumin was found to be linearly related to its concentration in the range of 3.0 × 10-8 M to 6.0 × 10-7 M with a detection limit of 2.2 × 10-8 M. It was also found that the novel Al3+/PdNp/GE electrode had the best sensitivity when compared to glassy carbon electrode (GCE), hanging mercury drop electrode (HMDE) and glassy carbon electrode electropolymerized with acid chrome blue K (poly-ACBK/GCE), used for the determination of curcumin. The curcumin was detected in marketed spices sample of turmeric powder. Pure turmeric powder had the highest curcumin concentration, averaging 4.317 ± 0.175% by weight. © 2015, Croatian Chemical Society. All rights reserved.en_US
dc.identifier.doi10.5562/cca2527
dc.identifier.endpage112en_US
dc.identifier.issn0011-1643
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-84938597850
dc.identifier.scopusqualityQ4
dc.identifier.startpage105en_US
dc.identifier.urihttps://doi.org/10.5562/cca2527
dc.identifier.volume88en_US
dc.identifier.wosWOS:000358441800002
dc.identifier.wosqualityQ4
dc.language.isoenen_US
dc.publisherCroatian Chemical Societyen_US
dc.relation.ispartofCroatica Chemica Actaen_US
dc.relation.journalCroatica Chemica Actaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAl3+ Ionen_US
dc.subjectCurcuminen_US
dc.subjectModified Graphite Electrodeen_US
dc.subjectPalladium Nanoparticlesen_US
dc.subjectPhysical Depositionen_US
dc.titleA Newly Developed Electrocatalytic Oxidation and Voltammetric Determination of Curcumin at the Surface of PdNP-Graphite Electrode by an Aqueous Solution Process With Al3+en_US
dc.typeArticleen_US
dspace.entity.typePublication

Files