Publication: Potentiometric Monitoring of Cobalt in Beer Sample by Solid Contact Ion Selective Electrode
| dc.authorscopusid | 55013129200 | |
| dc.authorscopusid | 56511466800 | |
| dc.authorscopusid | 6701763136 | |
| dc.authorscopusid | 56110164500 | |
| dc.contributor.author | Eren, H. | |
| dc.contributor.author | Uzun, H. | |
| dc.contributor.author | Andaç, M. | |
| dc.contributor.author | Bilir, S. | |
| dc.date.accessioned | 2020-06-21T13:52:20Z | |
| dc.date.available | 2020-06-21T13:52:20Z | |
| dc.date.issued | 2014 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Eren] Hilal, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Uzun] Harun, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bilir] Seda, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | A new solid contact cobalt selective electrode was constructed with 4-tert-butylthiacalix[4]arene as ionophore. The best performance was observed with the membrane having an ionophore/polyvinyl chloride/sodium tetraphenylborate/nitrophenyl octyl ether ratio of 3.5:33:1.5:62 (w/w; mg). The electrode, under steady-state conditions, exhibited a working concentration range of 1 × 10-1 - 1 × 10-6 mol/L with a near-Nernstian slope of 25.3 mV/decade and a detection limit of 3.5 × 10-7 mol/L. The electrode had a very short response time (<10 seconds) and good reproducibility at a working pH range of 4.0-6.5. The electrode was used for 4 months without any significant change in its sensitivity. The potentiometric performance of the electrode in partially nonaqueous medium [up to 20 % (v/v) alcohol] was found satisfactory. The performance of the prepared electrode for the analysis of beer samples using direct potentiometric method is very encouraging. © 2014, Food and Drug Administration, Taiwan. Published by Elsevier Taiwan LLC. All rights reserved. | en_US |
| dc.identifier.doi | 10.1016/j.jfda.2014.03.003 | |
| dc.identifier.endpage | 417 | en_US |
| dc.identifier.issn | 1021-9498 | |
| dc.identifier.issn | 2224-6614 | |
| dc.identifier.issue | 4 | en_US |
| dc.identifier.pmid | 25408976 | |
| dc.identifier.scopus | 2-s2.0-84916931360 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 413 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/j.jfda.2014.03.003 | |
| dc.identifier.volume | 22 | en_US |
| dc.identifier.wos | WOS:000346623500003 | |
| dc.identifier.wosquality | Q2 | |
| dc.language.iso | en | en_US |
| dc.publisher | Elsevier Taiwan LLC | en_US |
| dc.relation.ispartof | Journal of Food and Drug Analysis | en_US |
| dc.relation.journal | Journal of Food and Drug Analysis | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Beer | en_US |
| dc.subject | Cobalt | en_US |
| dc.subject | Polyvinyl Chloride (PVC) Membrane | en_US |
| dc.subject | Potentiometry | en_US |
| dc.subject | Solid Contact | en_US |
| dc.title | Potentiometric Monitoring of Cobalt in Beer Sample by Solid Contact Ion Selective Electrode | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
