Publication:
Potentiometric Monitoring of Cobalt in Beer Sample by Solid Contact Ion Selective Electrode

dc.authorscopusid55013129200
dc.authorscopusid56511466800
dc.authorscopusid6701763136
dc.authorscopusid56110164500
dc.contributor.authorEren, H.
dc.contributor.authorUzun, H.
dc.contributor.authorAndaç, M.
dc.contributor.authorBilir, S.
dc.date.accessioned2020-06-21T13:52:20Z
dc.date.available2020-06-21T13:52:20Z
dc.date.issued2014
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Eren] Hilal, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Uzun] Harun, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bilir] Seda, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA new solid contact cobalt selective electrode was constructed with 4-tert-butylthiacalix[4]arene as ionophore. The best performance was observed with the membrane having an ionophore/polyvinyl chloride/sodium tetraphenylborate/nitrophenyl octyl ether ratio of 3.5:33:1.5:62 (w/w; mg). The electrode, under steady-state conditions, exhibited a working concentration range of 1 × 10-1 - 1 × 10-6 mol/L with a near-Nernstian slope of 25.3 mV/decade and a detection limit of 3.5 × 10-7 mol/L. The electrode had a very short response time (<10 seconds) and good reproducibility at a working pH range of 4.0-6.5. The electrode was used for 4 months without any significant change in its sensitivity. The potentiometric performance of the electrode in partially nonaqueous medium [up to 20 % (v/v) alcohol] was found satisfactory. The performance of the prepared electrode for the analysis of beer samples using direct potentiometric method is very encouraging. © 2014, Food and Drug Administration, Taiwan. Published by Elsevier Taiwan LLC. All rights reserved.en_US
dc.identifier.doi10.1016/j.jfda.2014.03.003
dc.identifier.endpage417en_US
dc.identifier.issn1021-9498
dc.identifier.issn2224-6614
dc.identifier.issue4en_US
dc.identifier.pmid25408976
dc.identifier.scopus2-s2.0-84916931360
dc.identifier.scopusqualityQ2
dc.identifier.startpage413en_US
dc.identifier.urihttps://doi.org/10.1016/j.jfda.2014.03.003
dc.identifier.volume22en_US
dc.identifier.wosWOS:000346623500003
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherElsevier Taiwan LLCen_US
dc.relation.ispartofJournal of Food and Drug Analysisen_US
dc.relation.journalJournal of Food and Drug Analysisen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBeeren_US
dc.subjectCobalten_US
dc.subjectPolyvinyl Chloride (PVC) Membraneen_US
dc.subjectPotentiometryen_US
dc.subjectSolid Contacten_US
dc.titlePotentiometric Monitoring of Cobalt in Beer Sample by Solid Contact Ion Selective Electrodeen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files