Publication:
Flow-Injection Spectrophotometric Determination of Cobalt(II) at Low μg L-1 Levels With 4-Benzylpiperidinedithiocarbamate

dc.authorscopusid6701763136
dc.authorscopusid55984370700
dc.authorscopusid6603596907
dc.authorscopusid56541528000
dc.contributor.authorAndaç, M.
dc.contributor.authorAsan, A.
dc.contributor.authorIşıldak, I.
dc.contributor.authorCesur, H.
dc.date.accessioned2020-06-21T15:49:17Z
dc.date.available2020-06-21T15:49:17Z
dc.date.issued2001
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Asan] Adem, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Işıldak] İbrahim, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Cesur] Hasan, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA rapid, sensitive and reproducible flow-injection (FI) analysis method is described for the spectrophotometric determination of cobalt(II) using 4-benzylpiperidinedithiocarbamate as a chromogenic reagent. The method involves the measurement of the absorbance of the colored cobalt(II)-(4-benzylpiperidinedithiocarbamate)<inf>2</inf> complex at 640 nm. In the system, a microcolumn (MC) containing strong cation-exchange resin was placed between injection manifold and spectrophotometer to increase interactions between cobalt(II) and reagent, and for preconcentration of cobalt(II). The linear range of the proposed FI method was 0.6-100 μgl-1, and the limit of detection (signal/noise = 3) was 0.1 μgl-1 for a 10 μl injection of cobalt(II) ion solution at a sampling rate of 60 h-1. The relative standard deviation (R.S.D.) for 0.6-100 μgl-1 cobalt(II) was <1.0% (n = 5). The precision and accuracy of the method were checked by analysis of certified reference metals, and the method was applied to river, sea and hot spring water samples. © 2001 Elsevier Science B.V.en_US
dc.identifier.doi10.1016/S0003-2670(01)00826-1
dc.identifier.endpage147en_US
dc.identifier.issn0003-2670
dc.identifier.issn1873-4324
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-0035946418
dc.identifier.scopusqualityQ1
dc.identifier.startpage143en_US
dc.identifier.urihttps://doi.org/10.1016/S0003-2670(01)00826-1
dc.identifier.urihttps://hdl.handle.net/20.500.12712/22194
dc.identifier.volume434en_US
dc.identifier.wosWOS:000168287200017
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherElsevier Science B.V.en_US
dc.relation.ispartofAnalytica Chimica Actaen_US
dc.relation.journalAnalytica Chimica Actaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCation-Exchange Resinen_US
dc.subjectChromogenic Reagenten_US
dc.subjectCobalt Determinationen_US
dc.subjectFlow-Injectionen_US
dc.titleFlow-Injection Spectrophotometric Determination of Cobalt(II) at Low μg L-1 Levels With 4-Benzylpiperidinedithiocarbamateen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files