Publication:
Apical Extrusion of Debris and Irrigant Using XP-Endo Finisher, EndoActivator, Passive Ultrasonic Irrigation or Syringe Irrigation

dc.contributor.authorSariyilmaz, Evren
dc.contributor.authorKeskin, Cangul
dc.contributor.authorIDSariyilmaz, Evren/0000-0003-1711-7056
dc.date.accessioned2020-06-21T13:10:51Z
dc.date.available2020-06-21T13:10:51Z
dc.date.issued2018
dc.departmentOMÜen_US
dc.department-temp[Sariyilmaz, Evren] Ordu Univ, Dept Endodont, Fac Med, Ordu, Turkey -- [Keskin, Cangul] Ondokuz Mayis Univ, Dept Endodont, Fac Dent, Samsun, Turkey --en_US
dc.description.abstractObjective: Extrusion of irrigant and debris into the periapical tissues is a potential risk for flare-ups during root canal treatment. The aim of this study was to evaluate the apically extruded debris and sodium hypochlorite during XP-Endo Finisher (XP-Endo) file use and compare with final irrigation techniques. The tested null hypothesis in this study was that there was no difference among the irrigation techniques. Materials and Methods: An agar gel model was prepared for 80 extracted single rooted human mandibular premolar teeth, which were prepared up to the apical size of #40. The samples were divided into four groups according to the final irrigation regime: conventional syringe irrigation, XP-Endo, passive ultrasonic irrigation (PUI), and EndoActivator (EA). The test apparatus was weighed before and after the experiment, and the amount of apically extruded debris and irrigant was calculated. Results: There was minimal irrigant and debris extrusion in all groups. No significant difference among the tested groups was detected (p>0.05). Conclusion: Using the PUI, XP-Endo file, or EA according to the manufacturers' instruction does not increase the extrusion risk.en_US
dc.identifier.doi10.4274/meandros.24008
dc.identifier.endpage131en_US
dc.identifier.issn2149-9063
dc.identifier.issue2en_US
dc.identifier.startpage127en_US
dc.identifier.urihttps://doi.org/10.4274/meandros.24008
dc.identifier.urihttps://hdl.handle.net/20.500.12712/11511
dc.identifier.volume19en_US
dc.identifier.wosWOS:000441983900004
dc.language.isoenen_US
dc.publisherGalenos Yayinciliken_US
dc.relation.journalMeandros Medical and Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectXP-Endo Finisheren_US
dc.subjectPassive Ultrasonic Irrigationen_US
dc.subjectSonic Irrigationen_US
dc.subjectApical Extrusionen_US
dc.titleApical Extrusion of Debris and Irrigant Using XP-Endo Finisher, EndoActivator, Passive Ultrasonic Irrigation or Syringe Irrigationen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files