Publication:
Computerized Tomographic Evaluation of Effects of Mandibular Anterior Repositioning on the Upper Airway: A Pilot Study

dc.authorscopusid56628622100
dc.authorscopusid6506910831
dc.authorscopusid14119432200
dc.authorscopusid8856333900
dc.authorscopusid6508260156
dc.contributor.authorÖg̈ütcen-Toller, M.
dc.contributor.authorSaraç, Y.Ş.
dc.contributor.authorÇakır-Özkan, N.
dc.contributor.authorSaraç, D.
dc.contributor.authorSakan, B.
dc.date.accessioned2020-06-21T15:38:31Z
dc.date.available2020-06-21T15:38:31Z
dc.date.issued2004
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ög̈ütcen-Toller] Melahat, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Konya, Trabzon, Turkey; [Saraç] Yakup Šinasi, Department of Prosthetic Dentistry, Faculty of Dentistry, Konya, Trabzon, Turkey; [Çakır-Özkan] Nilüfer, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Konya, Trabzon, Turkey; [Saraç] Duygu, Department of Prosthetic Dentistry, Faculty of Dentistry, Konya, Trabzon, Turkey; [Sakan] Banu Baglan, Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractStatement of problem Snoring is related to narrowing of the upper airway. Treatment options for snoring may have potential side effects or discomfort which may not be tolerated by some patients. Mandibular advancement devices may cause fewer negative side effects than other treatment modatlities and have been advocated as a treatment for snoring. Purpose The aim of the pilot study was to evaluate effects of the anterior mandibular positioner (AMP) on upper airway structures in patients with a snoring problem. Material and methods Fifteen subjects with snoring problems as identified by spouses or close relatives were selected to complete a questionnaire related to snoring, respiratory symptoms, body mass index (BMI), and smoking habits. Computerized tomography (CT) scans were obtained with and without AMP device fabricated as a monoblock of acrylic resin. Measurements of the oropharynx including length (mm), cross-sectional area (mm2), and plane angle (degrees) were made using anatomic landmarks on standardized CT images and lateral scanograms. The data were statistically evaluated using Wilcoxon signed rank test (α=.05). Results When the AMP was inserted, the cross-sectional area of the oropharynx increased by 60 mm2 on average (P<.05). A mean increase of 2.4 mm (range 1-7 mm) was observed in the posterior airway space on lateral scanograms (P<.005). The range for mandibular advancement was between 4 and 8 mm (mean 5.73 mm). Conclusion The primary effect of the AMP was enlargement of the oropharyngeal airway. Within the limitations of this pilot study, the results suggest that CT evaluation of the upper airway structures may be helpful in determining treatment modality and monitoring the effectiveness of the positioner.en_US
dc.identifier.doi10.1016/j.prosdent.2004.05.003
dc.identifier.endpage189en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue2en_US
dc.identifier.pmid15295329
dc.identifier.scopus2-s2.0-4143099337
dc.identifier.scopusqualityQ1
dc.identifier.startpage184en_US
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2004.05.003
dc.identifier.volume92en_US
dc.identifier.wosWOS:000223287700015
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofJournal of Prosthetic Dentistryen_US
dc.relation.journalJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleComputerized Tomographic Evaluation of Effects of Mandibular Anterior Repositioning on the Upper Airway: A Pilot Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files