Publication:
Energy Consumption of Twisted File Instrument Used With Rotary or Reciprocating Adaptive Motion

dc.authorscopusid56348812200
dc.authorscopusid56471565700
dc.authorscopusid26967545200
dc.contributor.authorOzyurek, T.
dc.contributor.authorKeskin, C.
dc.contributor.authorÖzsezer Demi̇Ryürek, E.O.
dc.date.accessioned2020-06-21T09:42:29Z
dc.date.available2020-06-21T09:42:29Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ozyurek] Taha, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Keskin] Cangül, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Özsezer Demi̇Ryürek] Ebru, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractObjective: The aim of this study was to compare the energy consumption of Twisted File (TF) instrument used with rotary or adaptive motion (AM). Materials and Methods: Forty S-shaped Endo Training Blocks (Dentsply Maillefer) were used. Twenty were prepared using TF 25.06 in rotary motion (RM) group, and 20 were prepared using TF Adaptive SM2 in AM group. While engine-driven endodontic motors were connected to a digital wattmeter, the required torque for root canal instrumentation was analyzed by evaluating the electrical power consumption of the endodontic engine. Electric power consumption (mW/h), elapsed time (s), and a number of pecking motions required to reach the full working length (WL) were calculated. The data was statistically analyzed using Mann-Whitney U-test (P < 0.05). Results: Electrical power consumption during the preparation was significantly different between the groups; RM group exerted less electric power than reciprocating AM group did (P < 0.001). The required time to reach the full WL was not statistically significant between groups (P = 0.137). Conclusion: Within the limitation of this study, RM group exerted less electric power than reciprocating AM group did.en_US
dc.identifier.doi10.4103/2278-9626.179537
dc.identifier.endpage68en_US
dc.identifier.issn2278-9626
dc.identifier.issn2320-4753
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-85009168731
dc.identifier.scopusqualityQ4
dc.identifier.startpage65en_US
dc.identifier.urihttps://doi.org/10.4103/2278-9626.179537
dc.identifier.volume5en_US
dc.language.isoenen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.relation.ispartofEuropean Journal of General Dentistryen_US
dc.relation.journalEuropean Journal of General Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectElectric Power Consumptionen_US
dc.subjectNickel-Titaniumen_US
dc.subjectNickel-Titanium Rotary Preparationen_US
dc.subjectTwisted File Adaptiveen_US
dc.titleEnergy Consumption of Twisted File Instrument Used With Rotary or Reciprocating Adaptive Motionen_US
dc.typeArticleen_US
dspace.entity.typePublication