Publication: Quantitative Analysis of Root Canal System and Apical Part With Vertucci Type II Configuration Following Preparation with Three Different Preparation Systems: A Micro-Computed Tomography Study
| dc.authorscopusid | 8731395200 | |
| dc.authorscopusid | 56471565700 | |
| dc.contributor.author | Keleş, A. | |
| dc.contributor.author | Keskin, C. | |
| dc.date.accessioned | 2020-06-21T12:18:46Z | |
| dc.date.available | 2020-06-21T12:18:46Z | |
| dc.date.issued | 2020 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Keleş] Ali, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Keskin] Cangül, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | Objective: Isthmuses are narrow communications between root canals, and form as the result of the merging of the two root canals widening in a buccolingual direction. This widening causes the high ovality of isthmuses. The shaping and cleaning of all root canal systems are regarded as one of the major difficulties in long-oval shaped root canals. This study aims to make quantitative analysis of Vertucci type II root canal systems following preparation with Self-Adjusting file (SAF), Reciproc or Revo-S. Methods: Major diameter and roundness values were measured at the level 1.2 mm from apical foramen before and after preparation. A ‘post-preparation node’ point was described when the minimum minor diameter value was smaller than major diameter of apical 1.2 mm. Data were analysed using one-way ANOVA, Tukey and Chi-square tests. Results: Preparation resulted in a significant increase in the major diameter values regardless of the instrumentation (p = 0.000). Preparation with Reciproc led to the significant increase in roundness values (p = 0.000), whereas no significant difference was detected in specimens prepared with SAF (p = 0.21) and Revo-S (p = 0.15). Conclusion: Root canal preparation with SAF, Reciproc and Revo-S led to a significant increase in the major diameter of apical 1.2 mm and resulted in high frequencies of the post-preparation node. © 2020 Bentham Science Publishers. | en_US |
| dc.identifier.doi | 10.2174/1573405614666181115115352 | |
| dc.identifier.endpage | 443 | en_US |
| dc.identifier.issn | 1573-4056 | |
| dc.identifier.issn | 1875-6603 | |
| dc.identifier.issue | 4 | en_US |
| dc.identifier.pmid | 32410544 | |
| dc.identifier.scopus | 2-s2.0-85083076040 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 438 | en_US |
| dc.identifier.uri | https://doi.org/10.2174/1573405614666181115115352 | |
| dc.identifier.volume | 16 | en_US |
| dc.identifier.wos | WOS:000537883000009 | |
| dc.identifier.wosquality | Q4 | |
| dc.language.iso | en | en_US |
| dc.publisher | Bentham Science Publishers P.O. Box 294 Bussum 1400 AG | en_US |
| dc.relation.ispartof | Current Medical Imaging | en_US |
| dc.relation.journal | Current Medical Imaging | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Buccolingual | en_US |
| dc.subject | Endodontics | en_US |
| dc.subject | Instrumentation | en_US |
| dc.subject | Isthmuses | en_US |
| dc.subject | Micro-Computed Tomography | en_US |
| dc.subject | Root Canal Anatomy | en_US |
| dc.title | Quantitative Analysis of Root Canal System and Apical Part With Vertucci Type II Configuration Following Preparation with Three Different Preparation Systems: A Micro-Computed Tomography Study | en_US |
| dc.type | Article | en_US |