Publication: Effect of Different Heat-Treated Nickel-Titanium Files on Vertical Root Fracture Resistance
| dc.authorwosid | Furuncuoğlu, Fatma/C-4689-2019 | |
| dc.contributor.author | Furuncuoglu, Fatma | |
| dc.contributor.author | Kalyoncuoglu, Elif | |
| dc.contributor.authorID | 0000-0003-2784-3975 | en_US |
| dc.contributor.authorID | Furuncuoğlu, Fatma/0000-0001-5986-1508 | |
| dc.contributor.authorID | Kalyoncuoglu, Elif/0000-0003-2784-3975 | |
| dc.date.accessioned | 2022-05-18T12:25:59Z | |
| dc.date.available | 2022-05-18T12:25:59Z | |
| dc.date.issued | 2021 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Furuncuoglu, Fatma] Sakarya Univ, Dept Endodont, Fac Dent, Sakarya, Turkey; [Kalyoncuoglu, Elif] Ondokuz Mayis Univ, Dept Endodont, Fac Dent, Samsun, Turkey | en_US |
| dc.description | Furuncuoğlu, Fatma/0000-0001-5986-1508; Kalyoncuoglu, Elif/0000-0003-2784-3975 | en_US |
| dc.description.abstract | Objective: This study aimed to evaluate the fracture resistance of teeth instrumented with rotary files manufactured from different heat-treated nickel-titanium (NiTi) wires. Materials and Methods: One hundred extracted single-canal mandibular premolar teeth were sectioned, leaving a standard root length of 13 mm. Samples were matched with respect to the buccolingual-mesiodistal diameters. They were randomly divided into four experimental groups and one control group (n=20): Control group, no preparation or obturation; ProTaper Universal (PTU) group, prepared with the PTU system as a universal NiTi; Twisted File (TF) group, prepared with the TF system as an R-phase treatment; ProTaper Next (PTN) group, prepared with the PTN system as an M-Wire thermal treatment; and HyFlex Controlled Memory (HCM) group, prepared with the HCM system as a CM-Wire thermal treatment. After preparations, samples were obturated with gutta-percha and sealer. Samples were subjected to a vertical loading force of 1 mm/min until fracture occurred. Data were subjected to statistical analysis using One-way ANOVA (p=0.05) and Tukey tests. Results: Although the control group had the highest root fracture resistance value, the differences between the control group and HCM group was not significant (p>0.05). Except for the control group, the differences among the study groups were not significant (p>0.05). Conclusion: Different heat treatments of instruments have no effects on vertical root fracture resistance. | en_US |
| dc.description.sponsorship | Ondokuz Mayis University Scientific Research Projects Coordination Unit [PYO.DIS.1904.14.008] | en_US |
| dc.description.sponsorship | The Ondokuz Mayis University Scientific Research Projects Coordination Unit support this study financially (PYO.DIS.1904.14.008). | en_US |
| dc.description.woscitationindex | Emerging Sources Citation Index | |
| dc.identifier.citation | FURUNCUOĞLU F,KALYONCUOĞLU E (2021). Effect of Different Heat-treated NickelTitanium Files on Vertical Root Fracture Resistance. Meandros Medical And Dental Journal, 22(2), 157 - 163. Doi: 10.4274/meandros.galenos.2021.77699. | en_US |
| dc.identifier.doi | 10.4274/meandros.galenos.2021.77699 | |
| dc.identifier.endpage | 163 | en_US |
| dc.identifier.issn | 2149-9063 | |
| dc.identifier.issue | 2 | en_US |
| dc.identifier.startpage | 157 | en_US |
| dc.identifier.trdizinid | 459193 | |
| dc.identifier.uri | https://doi.org/10.4274/meandros.galenos.2021.77699 | |
| dc.identifier.uri | https://search.trdizin.gov.tr/en/yayin/detay/459193/effect-of-different-heat-treated-nickeltitanium-files-on-vertical-root-fracture-resistance | |
| dc.identifier.volume | 22 | en_US |
| dc.identifier.wos | WOS:000648668200006 | |
| dc.language.iso | en | en_US |
| dc.publisher | Galenos Yayincilik | en_US |
| dc.relation.ispartof | Meandros Medical and Dental Journal | en_US |
| dc.relation.journal | Meandros Medical And Dental Journal | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | CM-Wire | en_US |
| dc.subject | Instron | en_US |
| dc.subject | M-Wire | en_US |
| dc.subject | Thermal Treatment | en_US |
| dc.subject | Vertical Root Fracture | en_US |
| dc.title | Effect of Different Heat-Treated Nickel-Titanium Files on Vertical Root Fracture Resistance | en_US |
| dc.title.alternative | Farklı Isıl İşlem ile Üretilmiş Nikel-Titanyum Eğelerin Vertikal Kök Kırık Direncine Etkisi | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- d6a57c7f-ef97-4427-af44-6a197c83c575.pdf
- Size:
- 489.44 KB
- Format:
- Adobe Portable Document Format
- Description:
- Tam Metin / Full Text
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.44 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
