Publication:
Effect of Different Heat-Treated Nickel-Titanium Files on Vertical Root Fracture Resistance

dc.authorwosidFuruncuoğlu, Fatma/C-4689-2019
dc.contributor.authorFuruncuoglu, Fatma
dc.contributor.authorKalyoncuoglu, Elif
dc.contributor.authorID0000-0003-2784-3975en_US
dc.contributor.authorIDFuruncuoğlu, Fatma/0000-0001-5986-1508
dc.contributor.authorIDKalyoncuoglu, Elif/0000-0003-2784-3975
dc.date.accessioned2022-05-18T12:25:59Z
dc.date.available2022-05-18T12:25:59Z
dc.date.issued2021
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Furuncuoglu, Fatma] Sakarya Univ, Dept Endodont, Fac Dent, Sakarya, Turkey; [Kalyoncuoglu, Elif] Ondokuz Mayis Univ, Dept Endodont, Fac Dent, Samsun, Turkeyen_US
dc.descriptionFuruncuoğlu, Fatma/0000-0001-5986-1508; Kalyoncuoglu, Elif/0000-0003-2784-3975en_US
dc.description.abstractObjective: This study aimed to evaluate the fracture resistance of teeth instrumented with rotary files manufactured from different heat-treated nickel-titanium (NiTi) wires. Materials and Methods: One hundred extracted single-canal mandibular premolar teeth were sectioned, leaving a standard root length of 13 mm. Samples were matched with respect to the buccolingual-mesiodistal diameters. They were randomly divided into four experimental groups and one control group (n=20): Control group, no preparation or obturation; ProTaper Universal (PTU) group, prepared with the PTU system as a universal NiTi; Twisted File (TF) group, prepared with the TF system as an R-phase treatment; ProTaper Next (PTN) group, prepared with the PTN system as an M-Wire thermal treatment; and HyFlex Controlled Memory (HCM) group, prepared with the HCM system as a CM-Wire thermal treatment. After preparations, samples were obturated with gutta-percha and sealer. Samples were subjected to a vertical loading force of 1 mm/min until fracture occurred. Data were subjected to statistical analysis using One-way ANOVA (p=0.05) and Tukey tests. Results: Although the control group had the highest root fracture resistance value, the differences between the control group and HCM group was not significant (p>0.05). Except for the control group, the differences among the study groups were not significant (p>0.05). Conclusion: Different heat treatments of instruments have no effects on vertical root fracture resistance.en_US
dc.description.sponsorshipOndokuz Mayis University Scientific Research Projects Coordination Unit [PYO.DIS.1904.14.008]en_US
dc.description.sponsorshipThe Ondokuz Mayis University Scientific Research Projects Coordination Unit support this study financially (PYO.DIS.1904.14.008).en_US
dc.description.woscitationindexEmerging Sources Citation Index
dc.identifier.citationFURUNCUOĞLU F,KALYONCUOĞLU E (2021). Effect of Different Heat-treated NickelTitanium Files on Vertical Root Fracture Resistance. Meandros Medical And Dental Journal, 22(2), 157 - 163. Doi: 10.4274/meandros.galenos.2021.77699.en_US
dc.identifier.doi10.4274/meandros.galenos.2021.77699
dc.identifier.endpage163en_US
dc.identifier.issn2149-9063
dc.identifier.issue2en_US
dc.identifier.startpage157en_US
dc.identifier.trdizinid459193
dc.identifier.urihttps://doi.org/10.4274/meandros.galenos.2021.77699
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/459193/effect-of-different-heat-treated-nickeltitanium-files-on-vertical-root-fracture-resistance
dc.identifier.volume22en_US
dc.identifier.wosWOS:000648668200006
dc.language.isoenen_US
dc.publisherGalenos Yayinciliken_US
dc.relation.ispartofMeandros Medical and Dental Journalen_US
dc.relation.journalMeandros Medical And Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCM-Wireen_US
dc.subjectInstronen_US
dc.subjectM-Wireen_US
dc.subjectThermal Treatmenten_US
dc.subjectVertical Root Fractureen_US
dc.titleEffect of Different Heat-Treated Nickel-Titanium Files on Vertical Root Fracture Resistanceen_US
dc.title.alternativeFarklı Isıl İşlem ile Üretilmiş Nikel-Titanyum Eğelerin Vertikal Kök Kırık Direncine Etkisien_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
d6a57c7f-ef97-4427-af44-6a197c83c575.pdf
Size:
489.44 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: