Publication: The Effect of Breast Size and Density in Turkish Women on Radiation Dose in Full-Field Digital Mammography
| dc.authorscopusid | 55898513200 | |
| dc.authorscopusid | 56985325700 | |
| dc.authorscopusid | 37161967500 | |
| dc.authorwosid | Ozturk, Mesut/Kwt-5044-2024 | |
| dc.authorwosid | Polat, Ahmet/O-6352-2014 | |
| dc.contributor.author | Soylu, Ayşegül İdil | |
| dc.contributor.author | Öztürk, Mesut | |
| dc.contributor.author | Soylu, Ahmet Veysel | |
| dc.contributor.author | Soylu, Aysegul Idil | |
| dc.contributor.author | Ozturk, Mesut | |
| dc.contributor.author | Polat, Ahmet Veysel | |
| dc.contributor.authorID | 0000-0002-1390-1030 | en_US |
| dc.contributor.authorID | 0000-0002-9740-3580 | en_US |
| dc.contributor.authorID | Ozturk, Mesut/0000-0003-4059-2656 | |
| dc.contributor.authorID | Idil Soylu, Aysegül/0000-0002-1390-1030 | |
| dc.contributor.authorID | Polat, Ahmet Veysel/0000-0002-9740-3580 | |
| dc.date.accessioned | 2022-08-24T12:13:37Z | |
| dc.date.available | 2022-08-24T12:13:37Z | |
| dc.date.issued | 2021 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Soylu, Aysegul Idil; Polat, Ahmet Veysel] Ondokuz Mayis Univ, Dept Radiol, Fac Med, Samsun, Turkey; [Ozturk, Mesut] Samsun Gazi State Hosp, Dept Radiol, Samsun, Turkey | en_US |
| dc.description | ESCI | |
| dc.description | Ozturk, Mesut/0000-0003-4059-2656; Idil Soylu, Aysegül/0000-0002-1390-1030; Polat, Ahmet Veysel/0000-0002-9740-3580; | en_US |
| dc.description.abstract | Objective: The purpose of this study was to look into the relationship between breast size and mammographic breast density in women and breast radiation dose on full-field digital mammography (FFDM), as well as the factors that influence radiation dose. Materials and Methods: The study included a total of 2,060 FFDM images from 515 consecutive participants. The participants were divided into two groups: those exposed to high doses (>3 mGy) and those exposed to low doses (<3 mGy). Moreover, the researchers analyzed the relationship between mean glandular dose (MCD) of the breast and patient age, compressed breast thickness, compression force, mammographic breast composition, and mammographic breast size. Results: The mean mammographic breast volume was 936.2 +/- 425.2 (114.5-3,018) mL, and the mean compressed breast tissue thickness was 56.75 +/- 10.44 mm. Moreover, the mean MGD in the high-dose group was 3.51 +/- 0.48 mGy and 1.92 +/- 0.56 mGy in the low-dose group. The high-dose group had greater breast thickness, diameters, volume, compression pressure, and surgical rate. However, the high-dose group was younger and had less dense breasts. In multivariate logistic regression analysis, the most important predictors of dose determination were breast thickness [odds ratio (OR): 1.178, 95% confidence interval (CI): 1.156-1.200, p<0.001], history of previous surgery (OR: 2.210, 95% CI: 1.417-3.447, p<0.001), compression force (OR: 1.008, 95% CI: 1.004-1.013, p<0.001), and breast densiry (OR: 1.873, 95% CI: 1.359-2.580, p<0.001). Conclusion: Women with larger breast volumes arc subjected to higher doses of radiation. Therefore, breast-screening programs can be individualized to young women with larger breast volumes and women who have had breast-conserving surgery. | en_US |
| dc.description.woscitationindex | Emerging Sources Citation Index | |
| dc.identifier.citation | İdil Soylu A., Öztürk, M., Polat, A.V. (2021). The effect of breast size and density in Turkish women on radiation dose in full-field digital mammography. European Journal of Breast Health. 17(4), 29-33. Doi: 10.4274/ejbh.galenos.2021.6285 | en_US |
| dc.identifier.doi | 10.4274/ejbh.galenos.2021.6285 | |
| dc.identifier.endpage | 321 | en_US |
| dc.identifier.issn | 2587-0831 | |
| dc.identifier.issn | 2587-0831 | |
| dc.identifier.issue | 4 | en_US |
| dc.identifier.pmid | 34651109 | |
| dc.identifier.scopus | 2-s2.0-85149228705 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 315 | en_US |
| dc.identifier.trdizinid | 485094 | |
| dc.identifier.uri | http://doi.org/10.4274/ejbh.galenos.2021.6285 | |
| dc.identifier.uri | https://doi.org/10.4274/ejbh.galenos.2021.6285 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/33363 | |
| dc.identifier.uri | https://search.trdizin.gov.tr/en/yayin/detay/485094/the-effect-of-breast-size-and-density-in-turkish-women-on-radiation-dose-in-full-field-digital-mammography | |
| dc.identifier.uri | https://pubmed.ncbi.nlm.nih.gov/34651109/ | |
| dc.identifier.volume | 17 | en_US |
| dc.identifier.wos | WOS:000704610500004 | |
| dc.institutionauthor | Soylu, Ayşegül İdil | |
| dc.institutionauthor | Soylu, Ahmet Veysel | |
| dc.language.iso | en | en_US |
| dc.publisher | Galenos Publ House | en_US |
| dc.relation.ispartof | European Journal of Breast Health | en_US |
| dc.relation.journal | European Journal of Breast Health | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Breast Volume | en_US |
| dc.subject | Mammography | en_US |
| dc.subject | Radiation Dose | en_US |
| dc.title | The Effect of Breast Size and Density in Turkish Women on Radiation Dose in Full-Field Digital Mammography | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
