Publication:
The Effect of Breast Size and Density in Turkish Women on Radiation Dose in Full-Field Digital Mammography

dc.authorscopusid55898513200
dc.authorscopusid56985325700
dc.authorscopusid37161967500
dc.authorwosidOzturk, Mesut/Kwt-5044-2024
dc.authorwosidPolat, Ahmet/O-6352-2014
dc.contributor.authorSoylu, Ayşegül İdil
dc.contributor.authorÖztürk, Mesut
dc.contributor.authorSoylu, Ahmet Veysel
dc.contributor.authorSoylu, Aysegul Idil
dc.contributor.authorOzturk, Mesut
dc.contributor.authorPolat, Ahmet Veysel
dc.contributor.authorID0000-0002-1390-1030en_US
dc.contributor.authorID0000-0002-9740-3580en_US
dc.contributor.authorIDOzturk, Mesut/0000-0003-4059-2656
dc.contributor.authorIDIdil Soylu, Aysegül/0000-0002-1390-1030
dc.contributor.authorIDPolat, Ahmet Veysel/0000-0002-9740-3580
dc.date.accessioned2022-08-24T12:13:37Z
dc.date.available2022-08-24T12:13:37Z
dc.date.issued2021
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Soylu, Aysegul Idil; Polat, Ahmet Veysel] Ondokuz Mayis Univ, Dept Radiol, Fac Med, Samsun, Turkey; [Ozturk, Mesut] Samsun Gazi State Hosp, Dept Radiol, Samsun, Turkeyen_US
dc.descriptionESCI
dc.descriptionOzturk, Mesut/0000-0003-4059-2656; Idil Soylu, Aysegül/0000-0002-1390-1030; Polat, Ahmet Veysel/0000-0002-9740-3580;en_US
dc.description.abstractObjective: The purpose of this study was to look into the relationship between breast size and mammographic breast density in women and breast radiation dose on full-field digital mammography (FFDM), as well as the factors that influence radiation dose. Materials and Methods: The study included a total of 2,060 FFDM images from 515 consecutive participants. The participants were divided into two groups: those exposed to high doses (>3 mGy) and those exposed to low doses (<3 mGy). Moreover, the researchers analyzed the relationship between mean glandular dose (MCD) of the breast and patient age, compressed breast thickness, compression force, mammographic breast composition, and mammographic breast size. Results: The mean mammographic breast volume was 936.2 +/- 425.2 (114.5-3,018) mL, and the mean compressed breast tissue thickness was 56.75 +/- 10.44 mm. Moreover, the mean MGD in the high-dose group was 3.51 +/- 0.48 mGy and 1.92 +/- 0.56 mGy in the low-dose group. The high-dose group had greater breast thickness, diameters, volume, compression pressure, and surgical rate. However, the high-dose group was younger and had less dense breasts. In multivariate logistic regression analysis, the most important predictors of dose determination were breast thickness [odds ratio (OR): 1.178, 95% confidence interval (CI): 1.156-1.200, p<0.001], history of previous surgery (OR: 2.210, 95% CI: 1.417-3.447, p<0.001), compression force (OR: 1.008, 95% CI: 1.004-1.013, p<0.001), and breast densiry (OR: 1.873, 95% CI: 1.359-2.580, p<0.001). Conclusion: Women with larger breast volumes arc subjected to higher doses of radiation. Therefore, breast-screening programs can be individualized to young women with larger breast volumes and women who have had breast-conserving surgery.en_US
dc.description.woscitationindexEmerging Sources Citation Index
dc.identifier.citationİdil Soylu A., Öztürk, M., Polat, A.V. (2021). The effect of breast size and density in Turkish women on radiation dose in full-field digital mammography. European Journal of Breast Health. 17(4), 29-33. Doi: 10.4274/ejbh.galenos.2021.6285en_US
dc.identifier.doi10.4274/ejbh.galenos.2021.6285
dc.identifier.endpage321en_US
dc.identifier.issn2587-0831
dc.identifier.issn2587-0831
dc.identifier.issue4en_US
dc.identifier.pmid34651109
dc.identifier.scopus2-s2.0-85149228705
dc.identifier.scopusqualityQ3
dc.identifier.startpage315en_US
dc.identifier.trdizinid485094
dc.identifier.urihttp://doi.org/10.4274/ejbh.galenos.2021.6285
dc.identifier.urihttps://doi.org/10.4274/ejbh.galenos.2021.6285
dc.identifier.urihttps://hdl.handle.net/20.500.12712/33363
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/485094/the-effect-of-breast-size-and-density-in-turkish-women-on-radiation-dose-in-full-field-digital-mammography
dc.identifier.urihttps://pubmed.ncbi.nlm.nih.gov/34651109/
dc.identifier.volume17en_US
dc.identifier.wosWOS:000704610500004
dc.institutionauthorSoylu, Ayşegül İdil
dc.institutionauthorSoylu, Ahmet Veysel
dc.language.isoenen_US
dc.publisherGalenos Publ Houseen_US
dc.relation.ispartofEuropean Journal of Breast Healthen_US
dc.relation.journalEuropean Journal of Breast Healthen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBreast Volumeen_US
dc.subjectMammographyen_US
dc.subjectRadiation Doseen_US
dc.titleThe Effect of Breast Size and Density in Turkish Women on Radiation Dose in Full-Field Digital Mammographyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
document.pdf
Size:
1.1 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: