Publication:
Accuracy of Sphygmanometers at Pharmacies

dc.authorscopusid36904403900
dc.authorscopusid35271904500
dc.authorscopusid6602658770
dc.authorscopusid24402547900
dc.authorscopusid13807814200
dc.authorscopusid35199561300
dc.authorscopusid35200033200
dc.contributor.authorErdem, D.G.
dc.contributor.authorErdem, E.
dc.contributor.authorDilek, M.
dc.contributor.authorAydogdu, T.
dc.contributor.authorSelim, N.
dc.contributor.authorDemiray, F.
dc.contributor.authorSari, A.
dc.date.accessioned2020-06-21T15:08:34Z
dc.date.available2020-06-21T15:08:34Z
dc.date.issued2009
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Erdem] Dilek Gurgenyatagi, Department of Internal Medicine, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Erdem] Emre, Department of Internal Medicine, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Dilek] Melda, Department of Nephrology, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Aydogdu] Türkan, Department of Nephrology, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Selim] Nevzat, Department of Internal Medicine, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Demiray] Feride, Department of Internal Medicine, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Sari] Aysel, Department of Internal Medicine, Ondokuz Mayis University, Medical School, Samsun, Turkey; [Akpolat] Tekin, Department of Nephrology, Ondokuz Mayis University, Medical School, Samsun, Turkey, Tip Fakültesi Algoloji Bilim Dali, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractBackground/Aims: The aims of this study are to assess the reasons of using sphygmomanometers at pharmacies and to evaluate their accuracy. Methods: 135 devices (118 aneroid, 1 mercury, and 16 automated) from 125 pharmacies (located in Samsun city center) were included in the study. A non-randomized, cross-sectional design was used for the study protocol which had two parts: assessment of devices and a questionnaire about the pharmacy and present sphygmomanometer(s). Results: 40 (30%) of the 135 sphygmomanometers were inaccurate. 65 (48%) of the devices were older than 1 year and there was no correlation between the duration of the ownership of the sphygmomanometers and their inaccuracy (p > 0.05). Blood pressure measurement is a frequent practice at pharmacies. The aneroid type of sphygmomanometers was common. A limited number of devices were checked for accuracy before. The number of validated devices was low. Conclusion: Training programs for pharmacists including the accuracy of sphygmomanometers and regular checks of sphygmomanometers for accuracy will be beneficial to the community and to the subjects requesting measurement of blood pressure at the pharmacies. Copyright © 2009 S. Karger AG, Basel.en_US
dc.identifier.doi10.1159/000228936
dc.identifier.endpage234en_US
dc.identifier.issn1420-4096
dc.identifier.issn1423-0143
dc.identifier.issue4en_US
dc.identifier.pmid19622898
dc.identifier.scopus2-s2.0-70350286053
dc.identifier.scopusqualityQ2
dc.identifier.startpage231en_US
dc.identifier.urihttps://doi.org/10.1159/000228936
dc.identifier.volume32en_US
dc.identifier.wosWOS:000270553600001
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherKargeren_US
dc.relation.ispartofKidney & Blood Pressure Researchen_US
dc.relation.journalKidney & Blood Pressure Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBlood Pressureen_US
dc.subjectHypertensionen_US
dc.subjectPharmacy Sphygmomanometers, Accuracyen_US
dc.subjectSphygmomanometer, Pharmaciesen_US
dc.titleAccuracy of Sphygmanometers at Pharmaciesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files