Publication: A Flow-Injection Potentiometric System for Selective and Sensitive Determination of Serum Lithium Level
| dc.authorscopusid | 25921912000 | |
| dc.authorscopusid | 6701763136 | |
| dc.contributor.author | Coldur, F. | |
| dc.contributor.author | Andaç, M. | |
| dc.date.accessioned | 2020-06-21T14:06:28Z | |
| dc.date.available | 2020-06-21T14:06:28Z | |
| dc.date.issued | 2013 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Coldur] Fatih, Department of Chemistry, Erzincan Binali Yıldırım Üniversitesi, Erzincan, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | A potentiometric flow injection system was adopted by using a Li+-selective electrode with improved selectivity for sensitive and selective determination of Li+ in human serum spiked samples. For the optimization of the offered flow injection system, multivariate method was utilized. Potentiometric characteristics of the system were investigated (linear range: 5.0×10-5-1.0×10-1molL-1, slope: 56.93mV per decade, detection limit: 3.4×10-5molL-1, sampling-rate: 40 injections per hour). The detection of Li+ in real serum samples was achieved. The obtained results for the spiked serum samples were in good agreement with IC results at 95% confidence level. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. | en_US |
| dc.identifier.doi | 10.1002/elan.201200466 | |
| dc.identifier.endpage | 740 | en_US |
| dc.identifier.issn | 1040-0397 | |
| dc.identifier.issn | 1521-4109 | |
| dc.identifier.issue | 3 | en_US |
| dc.identifier.scopus | 2-s2.0-84874961982 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 732 | en_US |
| dc.identifier.uri | https://doi.org/10.1002/elan.201200466 | |
| dc.identifier.volume | 25 | en_US |
| dc.identifier.wos | WOS:000316213900021 | |
| dc.identifier.wosquality | Q3 | |
| dc.language.iso | en | en_US |
| dc.publisher | Wiley-VCH Verlag | en_US |
| dc.relation.ispartof | Electroanalysis | en_US |
| dc.relation.journal | Electroanalysis | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Experimental Design | en_US |
| dc.subject | Flow Injection Analysis | en_US |
| dc.subject | Lithium Determination | en_US |
| dc.subject | Multivariate Optimization | en_US |
| dc.subject | Serum Analysis | en_US |
| dc.title | A Flow-Injection Potentiometric System for Selective and Sensitive Determination of Serum Lithium Level | en_US |
| dc.type | Article | en_US |