Publication:
Diagnostic Accuracy of Sagittal TSE-T2w, Variable Flip Angle 3D TSE-T2w and High-Resolution 3D Heavily T2w Sequences for the Stenosis of Two Localizations: The Cerebral Aqueduct and the Superior Medullary Velum

dc.authorscopusid37095683700
dc.authorscopusid52663264000
dc.authorwosidŞirin Özcan, Ayşe Nur/Aay-8110-2021
dc.contributor.authorOzcan, Ayse Nur Sirin
dc.contributor.authorAslan, Kerim
dc.contributor.authorIDAslan, Kerim/0000-0001-6322-7163
dc.date.accessioned2025-12-11T00:51:56Z
dc.date.issued2021
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ozcan, Ayse Nur Sirin] Ankara Bilkent City Hosp, Dept Radiol, Ankara, Turkey; [Aslan, Kerim] Samsun Ondokuz Mayis Univ, Dept Radiol, Samsun, Turkeyen_US
dc.descriptionAslan, Kerim/0000-0001-6322-7163en_US
dc.description.abstractObjectives: This study aimed to investigate the accuracy of conventional Sagittal Turbo spin Echo T2-weighted (Sag TSE-T2W), variable flip angle 3D TSE (VFA-3D-TSE) and high -resolution 3D heavily T2W (HR-3D-HT2W) sequences in the diagnosis of primary aqueductal stenosis (PAS) and Superior Medullary Velum Stenosis (SMV-S), and the effect of stenosis localization on diagnosis. Methods: Seventy-seven patients were included in the study. The diagnosis accuracy of the HR-3D-HT2W, Sag TSE-T2W and VFA-3D-TSE sequences, was classified into three grades by two experienced neuroradiologists: grade 0 (the sequence has no diagnostic ability), grade 1 (the sequence diagnoses stenosis but does not show focal stenosis itself or membrane formation), and grade 2 (the sequence makes a definitive diagnosis of stenosis and shows focal stenosis itself or membrane formation). Stenosis localizations were divided into three as Cerebral Aquaduct (CA), Superior Medullary Velum (SMV) and SMV+CA. In the statistical analysis, the grades of the sequences were compared without making a differentiation based on localization. Then, the effect of localization on diagnosis was determined by comparing the grades for individual localizations. Results: In the sequence comparison, grade 0 was not detected in the VFA-3D-TSE and HR-3DHT2W sequences, and these sequences diagnosed all cases. On the other hand, 25.4% of grade 0 was detected with the Sag TSE-T2W sequence (P<0.05). Grade 1 was detected by VFA-3D-TSE in 23% of the cases, while grade 1 (12.5%) was detected by HRH-3D-T2W in only one case, and the difference was statistically significant (P<0.05). When the sequences were examined according to localizations, the rate of grade 0 in the Sag TSE-T2W sequence was statistically significantly higher for the SMV localization (33.3%) compared to CA (66.7%) and SMV+CA (0%) (P<0.05). Localization had no effect on diagnosis using the other sequences. Conclusion: In our study, we found that the VFA-3D-TSE and HR-3D-HT2W sequences were successful in the diagnosis of PAS and SMV-S contrary to the Sag TSE-T2W sequence and especially SMV localization decreases the diagnostic accuracy of Sag TSE-T2W sequence.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.2174/1573405617666210806123720
dc.identifier.endpage1438en_US
dc.identifier.issn1573-4056
dc.identifier.issn1875-6603
dc.identifier.issue12en_US
dc.identifier.pmid34365953
dc.identifier.scopus2-s2.0-85123324934
dc.identifier.scopusqualityQ3
dc.identifier.startpage1432en_US
dc.identifier.urihttps://doi.org/10.2174/1573405617666210806123720
dc.identifier.urihttps://hdl.handle.net/20.500.12712/39803
dc.identifier.volume17en_US
dc.identifier.wosWOS:000737944200005
dc.identifier.wosqualityQ4
dc.language.isoenen_US
dc.publisherBentham Science Publ Ltden_US
dc.relation.ispartofCurrent Medical Imagingen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHydrocephalusen_US
dc.subjectNon-Communicating Hydrocephalusen_US
dc.subjectAqueductal Stenosisen_US
dc.subjectSuperior Medullary Velum Stenosisen_US
dc.subjectHigh-Resolution 3D Heavily T2Wen_US
dc.subjectVariable Flip Angle 3D TSEen_US
dc.titleDiagnostic Accuracy of Sagittal TSE-T2w, Variable Flip Angle 3D TSE-T2w and High-Resolution 3D Heavily T2w Sequences for the Stenosis of Two Localizations: The Cerebral Aqueduct and the Superior Medullary Velumen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files