Publication: Diagnostic Accuracy of Sagittal TSE-T2w, Variable Flip Angle 3D TSE-T2w and High-Resolution 3D Heavily T2w Sequences for the Stenosis of Two Localizations: The Cerebral Aqueduct and the Superior Medullary Velum
| dc.authorscopusid | 37095683700 | |
| dc.authorscopusid | 52663264000 | |
| dc.authorwosid | Şirin Özcan, Ayşe Nur/Aay-8110-2021 | |
| dc.contributor.author | Ozcan, Ayse Nur Sirin | |
| dc.contributor.author | Aslan, Kerim | |
| dc.contributor.authorID | Aslan, Kerim/0000-0001-6322-7163 | |
| dc.date.accessioned | 2025-12-11T00:51:56Z | |
| dc.date.issued | 2021 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Ozcan, Ayse Nur Sirin] Ankara Bilkent City Hosp, Dept Radiol, Ankara, Turkey; [Aslan, Kerim] Samsun Ondokuz Mayis Univ, Dept Radiol, Samsun, Turkey | en_US |
| dc.description | Aslan, Kerim/0000-0001-6322-7163 | en_US |
| dc.description.abstract | Objectives: This study aimed to investigate the accuracy of conventional Sagittal Turbo spin Echo T2-weighted (Sag TSE-T2W), variable flip angle 3D TSE (VFA-3D-TSE) and high -resolution 3D heavily T2W (HR-3D-HT2W) sequences in the diagnosis of primary aqueductal stenosis (PAS) and Superior Medullary Velum Stenosis (SMV-S), and the effect of stenosis localization on diagnosis. Methods: Seventy-seven patients were included in the study. The diagnosis accuracy of the HR-3D-HT2W, Sag TSE-T2W and VFA-3D-TSE sequences, was classified into three grades by two experienced neuroradiologists: grade 0 (the sequence has no diagnostic ability), grade 1 (the sequence diagnoses stenosis but does not show focal stenosis itself or membrane formation), and grade 2 (the sequence makes a definitive diagnosis of stenosis and shows focal stenosis itself or membrane formation). Stenosis localizations were divided into three as Cerebral Aquaduct (CA), Superior Medullary Velum (SMV) and SMV+CA. In the statistical analysis, the grades of the sequences were compared without making a differentiation based on localization. Then, the effect of localization on diagnosis was determined by comparing the grades for individual localizations. Results: In the sequence comparison, grade 0 was not detected in the VFA-3D-TSE and HR-3DHT2W sequences, and these sequences diagnosed all cases. On the other hand, 25.4% of grade 0 was detected with the Sag TSE-T2W sequence (P<0.05). Grade 1 was detected by VFA-3D-TSE in 23% of the cases, while grade 1 (12.5%) was detected by HRH-3D-T2W in only one case, and the difference was statistically significant (P<0.05). When the sequences were examined according to localizations, the rate of grade 0 in the Sag TSE-T2W sequence was statistically significantly higher for the SMV localization (33.3%) compared to CA (66.7%) and SMV+CA (0%) (P<0.05). Localization had no effect on diagnosis using the other sequences. Conclusion: In our study, we found that the VFA-3D-TSE and HR-3D-HT2W sequences were successful in the diagnosis of PAS and SMV-S contrary to the Sag TSE-T2W sequence and especially SMV localization decreases the diagnostic accuracy of Sag TSE-T2W sequence. | en_US |
| dc.description.woscitationindex | Science Citation Index Expanded | |
| dc.identifier.doi | 10.2174/1573405617666210806123720 | |
| dc.identifier.endpage | 1438 | en_US |
| dc.identifier.issn | 1573-4056 | |
| dc.identifier.issn | 1875-6603 | |
| dc.identifier.issue | 12 | en_US |
| dc.identifier.pmid | 34365953 | |
| dc.identifier.scopus | 2-s2.0-85123324934 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 1432 | en_US |
| dc.identifier.uri | https://doi.org/10.2174/1573405617666210806123720 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/39803 | |
| dc.identifier.volume | 17 | en_US |
| dc.identifier.wos | WOS:000737944200005 | |
| dc.identifier.wosquality | Q4 | |
| dc.language.iso | en | en_US |
| dc.publisher | Bentham Science Publ Ltd | en_US |
| dc.relation.ispartof | Current Medical Imaging | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Hydrocephalus | en_US |
| dc.subject | Non-Communicating Hydrocephalus | en_US |
| dc.subject | Aqueductal Stenosis | en_US |
| dc.subject | Superior Medullary Velum Stenosis | en_US |
| dc.subject | High-Resolution 3D Heavily T2W | en_US |
| dc.subject | Variable Flip Angle 3D TSE | en_US |
| dc.title | Diagnostic Accuracy of Sagittal TSE-T2w, Variable Flip Angle 3D TSE-T2w and High-Resolution 3D Heavily T2w Sequences for the Stenosis of Two Localizations: The Cerebral Aqueduct and the Superior Medullary Velum | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |