Publication:
Effects of Staining and Bleaching Procedures on the Optical and Surface Properties of CAD-CAM Materials

dc.authorwosidBal, Lena/Hkm-9580-2023
dc.authorwosidInanc, Ibrahim/A-5624-2018
dc.contributor.authorYenidunya, Ozge Gizem
dc.contributor.authorGonulol, Niran
dc.contributor.authorMisilli, Tugba
dc.contributor.authorBal, Lena
dc.contributor.authorInanc, Ibrahim
dc.contributor.authorIDBal, Lena/0000-0003-3493-0137
dc.contributor.authorIDInanc, Ibrahim/0000-0003-1988-1197
dc.date.accessioned2025-12-11T01:17:57Z
dc.date.issued2023
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Yenidunya, Ozge Gizem] Pamukkale Univ, Dept Restorat Dent, Fac Dent, Denizli, Turkiye; [Gonulol, Niran] Ondokuz Mayis Univ, Fac Dent, Dept Restorat Dent, Samsun, Turkiye; [Inanc, Ibrahim] Ondokuz Mayis Univ, Dept Met & Mat Engn, Fac Engn, Samsun, Turkiye; [Misilli, Tugba] Canakkale Onsekiz Mart Univ, Dept Restorat Dent, Fac Dent, Canakkale, Turkiye; [Bal, Lena] Ankara Medipol Univ, Dept Restorat Dent, Fac Dent, Ankara, Turkiyeen_US
dc.descriptionBal, Lena/0000-0003-3493-0137; Inanc, Ibrahim/0000-0003-1988-1197;en_US
dc.description.abstractPurpose: To examine the effects of coffee staining and bleaching applications on the optical properties of CAD-CAM blocks, and to provide a three-dimensional visualization of surface changes with atomic force microscope (AFM). Methods: 80 samples were prepared from four different CAD-CAM blocks: [Cerec (CR), Shofu (SH), Cerasmart (CRS), Lava Ultimate (LU)], and a microhybrid composite resin [Filtek Z250 (Z250)]. After staining, the samples were divided into two subgroups according to bleaching methods: 16% carbamide peroxide (HB), and 40% hydrogen peroxide (OB). Color measurements were performed at baseline (t(0)), after staining (t(1)), and after bleaching (t(2)) to obtain translucency parameters (TP00), color change (AE(00)), and whiteness index (WID) values. Surface roughness analysis (Ra) was performed with AFM after coffee staining and bleaching procedures (at t(1), and t(2)). Data were analyzed with Generalized Linear Model, and Bonferroni correction (P< 0.05). Results: TP00 values increased only in the CRS group after the bleaching application, and the effect of method was again observed only in CRS. While bleaching increased WID values of all groups except CRS, no difference was found between bleaching methods. Regardless of evaluation time, the roughest group is Z250, and the only difference between bleaching methods was observed in the CR group. In conclusion, the effects of staining and bleaching applications on the optical and surface properties of CAD-CAM blocks are material-dependent.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey [119S792]en_US
dc.description.sponsorshipThe authors declared no conflict of interest. The research project was supported by the Scientific and Technological Research Council of Turkey [1002 Short Term R&D Funding Program/project number: 119S792].en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.endpage316en_US
dc.identifier.issn0894-8275
dc.identifier.issue6en_US
dc.identifier.pmid38092749
dc.identifier.scopusqualityQ3
dc.identifier.startpage310en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/42664
dc.identifier.volume36en_US
dc.identifier.wosWOS:001132430600007
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherMosher & Linder, Incen_US
dc.relation.ispartofAmerican Journal of Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEffects of Staining and Bleaching Procedures on the Optical and Surface Properties of CAD-CAM Materialsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files