Publication:
Bleaching Versus Color Change Resistant Adhesive in the Discoloration of Bracket-Bonded Tooth Surfaces: An in Vitro Study

dc.authorscopusid58124356300
dc.authorscopusid57197763101
dc.authorwosidYazicioğlu, Sabahat/Abi-3157-2020
dc.contributor.authorKaradeniz, Hasan
dc.contributor.authorYazicioglu, Sabahat
dc.contributor.authorIDKaradeni̇z, Hasan/0000-0003-4976-5162
dc.contributor.authorIDYazicioglu, Sabahat/0000-0001-9512-4935
dc.date.accessioned2025-12-11T01:23:36Z
dc.date.issued2024
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Karadeniz, Hasan] Giresun Oral & Dent Hlth Hosp, TR-28200 Giresun, Turkiye; [Yazicioglu, Sabahat] Univ Ondokuz Mayis, Fac Dent, Dept Orthodont, TR-55139 Samsun, Turkiyeen_US
dc.descriptionKaradeni̇z, Hasan/0000-0003-4976-5162; Yazicioglu, Sabahat/0000-0001-9512-4935en_US
dc.description.abstractObjectives The aim of this study was to compare the effect of office bleaching of teeth bonded with Transbond XT (TM) (3M Unitek, Monrovia, CA, USA) (TRXT) and the use of color change resistant Orthocem (FGM, Joinville, Brazil) in bracket bonding on coffee-induced enamel discoloration. Materials and methods Eighty premolars were distributed in equal numbers (n=20) to group 1 (TRXT+distilled water), group 2 (TRXT+coffee solution), group 3 (TRXT+coffee solution+bleaching), and group 4 (Orthocem+coffee solution). Color was measured using a SpectroShade Micro (MHT, International, Verona, Italy) device at the beginning (T0), after coloring (T1), after bleaching (T1B), and after debonding (T2). Delta E color change values were calculated as T1-T0, T1B-T0 and T2-T0 differences. The conformity of the data to the normal distribution was examined with the Shapiro-Wilk test. Multiple comparisons were made with Tamhane's T2 test and Tukey's HSD test using one-way analysis of variance in the comparison of normally distributed data, and multiple comparisons were made with Dunn's test using the Kruskal-Wallis H test for comparison of non-normally distributed data. The significance level was set at p<0.050. Results A statistically significant (p<0.001) difference was found between the T1-T0 and T2-T0 stages for group 1-4 Delta E values. A statistically significant (p<0.001) difference was also found when the T1B-T0 Delta E values of group 3 were compared with the T1-T0 Delta E values of groups 1, 2, and 4. Conclusions After coffee-induced enamel discoloration, bleaching of teeth bonded with TRXT produced acceptable color difference of the incisal, middle, and gingival regions of the crown. In teeth bonded with Orthocem, acceptable color difference was seen only in the middle of the crown.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkiye (TUBITAK)en_US
dc.description.sponsorshipOpen access funding provided by the Scientific and Technological Research Council of Turkiye (TUBITAK).en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1007/s00784-024-05668-5
dc.identifier.issn1432-6981
dc.identifier.issn1436-3771
dc.identifier.issue5en_US
dc.identifier.pmid38671235
dc.identifier.scopus2-s2.0-85191634042
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1007/s00784-024-05668-5
dc.identifier.urihttps://hdl.handle.net/20.500.12712/43389
dc.identifier.volume28en_US
dc.identifier.wosWOS:001336267100002
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherSpringer Heidelbergen_US
dc.relation.ispartofClinical Oral Investigationsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBleachingen_US
dc.subjectBracketen_US
dc.subjectColor Change Resistant Adhesiveen_US
dc.subjectDiscolorationen_US
dc.titleBleaching Versus Color Change Resistant Adhesive in the Discoloration of Bracket-Bonded Tooth Surfaces: An in Vitro Studyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files