Publication:
The Evaluation of Retinal Non-Perfusion With Multicolor Imaging in Diabetic Retinopathy

dc.authorscopusid57226147605
dc.authorscopusid54401920900
dc.authorscopusid24280274300
dc.authorscopusid6602733678
dc.contributor.authorKonuk, S.G.
dc.contributor.authorYücel, Ö.E.
dc.contributor.authorEser-Öztürk, H.E.
dc.contributor.authorSüllü, Y.
dc.contributor.authorID0000-0003-4014-6234en_US
dc.contributor.authorID0000-0002-0050-7894en_US
dc.contributor.authorID0000-0001-9818-671Xen_US
dc.date.accessioned2022-08-17T10:06:25Z
dc.date.available2022-08-17T10:06:25Z
dc.date.issued2021
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Konuk] Serife Gülhan, Tokat Gaziosmanpaşa Üniversitesi, Tokat, Turkey; [Yücel] Özlem Eşki, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Eser-Öztürk] Hilal, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Süllü] Ýüksel, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractPurpose: This study was conducted to evaluate the ability of multicolor (MC)-green refl ectance (GR) imaging in detecting retinal nonperfused areas (RNPAs) of eyes with diabetic retinopathy (DR). Materials and Methods: Fifty-fi ve degrees fundus fl uorescein angiography (FA) and MC imaging were performed in eyes with DR. Images were divided into four fi elds as macular, nasal, superior temporal, and inferior temporal. To determine the presence and size of RNPAs, FA images were examined by a retina specialist and MC-GR images were examined independently by two masked retina specialists. The compliance of RNPAs in FA and MC-GR images and the agreement of retina specialists were analyzed. Results: The FA and MC-GR images of the 178 eyes were analyzed. When GR images were compared to FA images in terms of RNPAs, sensitivity was 87%; specifi city was 89%; the positive predictive value was 92%; the negative predictive value was 83%; and the accuracy was 87%. A substantial agreement was observed between two retina specialists in all retinal fi elds. Conclusion: This study showed that 55° MC-GR imaging could be an alternative to FA in the evaluation of RNPAs. This study is the fi rst known to explore this issue and needs to be supported and developed with new investigations. © 2021 Gazi Eye Foundation. All rights reserved.en_US
dc.identifier.citationKonuk, Ş. G., Ekşi Yücel, Ö., Eser Öztürk, H. ve Süllü, Y. (2021). The The evaluation of retinal non-perfusion with multicolor imaging in diabetic retinopathy. Retina-Vitreus, 30(2), 139 - 145. Doi: 10.37845/ret.vit.2021.30.24en_US
dc.identifier.doi10.37845/ret.vit.2021.30.24
dc.identifier.endpage145en_US
dc.identifier.issn1300-1256
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-85110681623
dc.identifier.scopusqualityQ4
dc.identifier.startpage139en_US
dc.identifier.trdizinid505914
dc.identifier.urihttps://doi.org/10.37845/ret.vit.2021.30.24
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/505914/the-evaluation-of-retinal-non-perfusion-with-multicolor-imaging-in-diabetic-retinopathy
dc.identifier.volume30en_US
dc.language.isoenen_US
dc.publisherGazi Eye Foundationen_US
dc.relation.ispartofRetina-Vitreusen_US
dc.relation.journalRetina-Vitreousen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDiabetic Retinopathyen_US
dc.subjectGreen Reflectance Imagingen_US
dc.subjectMulticolor Imagingen_US
dc.subjectRetinal Ischemiaen_US
dc.subjectRetinal Non-Perfusionen_US
dc.titleThe Evaluation of Retinal Non-Perfusion With Multicolor Imaging in Diabetic Retinopathyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
uploads_pdf_PDF_EN_2046.pdf
Size:
406.86 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.44 KB
Format:
Item-specific license agreed upon to submission
Description: