Publication:
The pH Changes of Calcium Hydroxide Mixed With Six Different Vehicles

dc.authorscopusid56212055300
dc.authorscopusid16237906700
dc.authorscopusid14068418700
dc.authorscopusid16238460900
dc.contributor.authorYücel, A.Ç.
dc.contributor.authorAksoy, A.
dc.contributor.authorErtaş, E.
dc.contributor.authorGüvenç, D.
dc.date.accessioned2020-06-21T15:23:41Z
dc.date.available2020-06-21T15:23:41Z
dc.date.issued2007
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Yücel] Ali Çaǧin, Department of Restorative Dentistry and Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Aksoy] Abdurrahman, Department of Pharmacology and Toxicology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Ertaş] Ertan, Department of Restorative Dentistry and Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Güvenç] Dilek, Department of Pharmacology and Toxicology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractObjective: The aim of this study was to determine the pH values of calcium hydroxide mixed with sterile saline, glycerin, Xylocaine pump spray, Citanest Octapressin, 0.2% chlorhexidine solution, and Ultracaine DS. Study design: pH values of all vehicles were measured by a pH microelectrode before calcium hydroxide powder was added to 2 mL of the vehicle until the solutions were saturated (n = 10). After all the saturated samples were prepared, pH was remeasured at 0, 10, 20, 30, and 45 minutes; 1, 24, and 48 hours; and 7 days. Results: When pH changes over the time course were compared, there were no statistically significant differences among mean pH values of 0, 10, 20, 30, 45 minutes, 1 hour, and 24 hours (P = .754) and mean pH values of these groups were significantly lower than the mean pH value of 48 hours and 7 days (P < .05). The highest mean pH value was observed at day 7. When different vehicles were compared, the lowest mean pH value was observed in sterile saline. The mean pH value of Xylocaine was the highest (P < .05). Conclusion: The result of this study indicated that when calcium hydroxide powder was mixed with glycerin, Xylocaine pump spray, Citanest Octapressin, 0.2% chlorhexidine solution, Ultracaine DS, and sterile saline solution, the mixtures became very highly alkaline. However, the pH values of the mixtures increased significantly after 24 hours. When one of these vehicles is used for root canal medication, a calcium hydroxide mixture might be left in place at least 7 days. © 2007 Mosby, Inc. All rights reserved.en_US
dc.identifier.doi10.1016/j.tripleo.2006.10.016
dc.identifier.endpage717en_US
dc.identifier.issn1079-2104
dc.identifier.issue5en_US
dc.identifier.pmid17241800
dc.identifier.scopus2-s2.0-34247336871
dc.identifier.startpage712en_US
dc.identifier.urihttps://doi.org/10.1016/j.tripleo.2006.10.016
dc.identifier.urihttps://hdl.handle.net/20.500.12712/20012
dc.identifier.volume103en_US
dc.identifier.wosWOS:000248082300040
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodonticsen_US
dc.relation.journalOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleThe pH Changes of Calcium Hydroxide Mixed With Six Different Vehiclesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files