Publication:
The Coherence Between Fine Needle Aspiration Cytology and Histopathology of Palpable Neck Nodes in Lower Lip Carcinoma Patients

dc.authorscopusid6504058144
dc.authorscopusid56025760100
dc.authorscopusid56251306400
dc.authorscopusid6603888829
dc.authorscopusid6603773662
dc.contributor.authorGençoǧlu, U.
dc.contributor.authorGun̈eren, E.
dc.contributor.authorGözü, A.
dc.contributor.authorÖzsoy, Z.
dc.contributor.authorVural, G.
dc.date.accessioned2020-06-21T09:14:48Z
dc.date.available2020-06-21T09:14:48Z
dc.date.issued2003
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Gençoǧlu] Uǧur, Plastic Surgery Clinic, Gureba Hospital, Istanbul, Turkey; [Gun̈eren] Ethem, Div. of Plastic/Reconstructive Surg., Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Gözü] Aydin, Plastic Surgery Clinic, Gureba Hospital, Istanbul, Turkey; [Özsoy] Zafer, Plastic Surgery Clinic, Gureba Hospital, Istanbul, Turkey; [Vural] Gürcan,en_US
dc.description.abstractObtaining a preoperative diagnosis of palpable neck nodes in head and neck carcinoma patients provides accurate staging and allows a treatment plan to be established. Fine-needle aspiration cytology (FNAC) of palpable neck nodes was performed in 26 consecutive lower lip carcinoma patients. This resulted in 100% specificity, 88.8% accurate diagnosis, and 71.4% sensitivity; 83.4% of the mobile and soft neck masses which were examined were benign nodes (r=0.834). These results showed a consistency of the histopathological findings in this very particular patient group. The outpatient FNAC of neck masses was well tolerated by our patients. This procedure is safe, quick, and does not compromise the node dissection. Furthermore, the cost-effectiveness of FNAC makes it useful in disease staging.en_US
dc.identifier.doi10.1007/s00238-003-0483-z
dc.identifier.endpage84en_US
dc.identifier.issn1435-0130
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-0037635279
dc.identifier.scopusqualityQ3
dc.identifier.startpage82en_US
dc.identifier.urihttps://doi.org/10.1007/s00238-003-0483-z
dc.identifier.volume26en_US
dc.language.isoenen_US
dc.publisherSpringer Verlagen_US
dc.relation.ispartofEuropean Journal of Plastic Surgeryen_US
dc.relation.journalEuropean Journal of Plastic Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCervical Metastasesen_US
dc.subjectFine-Needle Aspiration Biopsyen_US
dc.subjectFine-Needle Aspiration Cytologyen_US
dc.subjectLower Lip Carcinomaen_US
dc.subjectNeck Nodesen_US
dc.titleThe Coherence Between Fine Needle Aspiration Cytology and Histopathology of Palpable Neck Nodes in Lower Lip Carcinoma Patientsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files