Publication:
Solid Phase Extraction and Preconcentration of Cu(II), Pb(II), and Ni(II) in Environmental Samples on Chemically Modified Amberlite XAD-4 With a Proper Schiff Base

dc.authorscopusid35747417800
dc.authorscopusid7004226302
dc.contributor.authorTopuz, B.
dc.contributor.authorMacit, M.
dc.date.accessioned2020-06-21T14:41:05Z
dc.date.available2020-06-21T14:41:05Z
dc.date.issued2011
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Topuz] Berrin, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Macit] Mustafa, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA new chelating resin, Amberlite XAD-4 loaded with N,N-bis(salicylidene) cyclohexanediamine (SCHD), was synthesized and characterized. The resin Amberlite XAD-4-SCHD was used for selective separation, preconcentration, and determination of Cu(II), Pb(II), and Ni(II) ions in water samples by flame atomic absorption spectrometry (FAAS). Effects of pH, concentration, and volume of elution solution; flow rate of elution; and sample solution, sample volume, and interfering ions for the recovery of the analytes were investigated. These metal ions can be desorbed with 0.5-M HNO<inf>3</inf> (recovery, 98%-101%). The sorption capacity was found between 1.38×10-1 and 3.58×10-1 mmol/g. In order to evaluate the accuracy of the proposed procedure, the certified reference materials, BCR-032 (Moroccan phosphate rock) and BCR-715 (industrial effluent wastewater), were analyzed. The detection limits of the method were found to be 0.11, 1.91, and 0.43 μg/L for Cu(II), Pb(II), and Ni(II), respectively. The method was applied to the extraction and the recovery of copper, lead, and nickel in wastewater and other water samples. © 2010 Springer Science+Business Media B.V.en_US
dc.identifier.doi10.1007/s10661-010-1417-4
dc.identifier.endpage722en_US
dc.identifier.issn0167-6369
dc.identifier.issn1573-2959
dc.identifier.pmid20237836
dc.identifier.scopus2-s2.0-79151481947
dc.identifier.scopusqualityQ2
dc.identifier.startpage709en_US
dc.identifier.urihttps://doi.org/10.1007/s10661-010-1417-4
dc.identifier.volume173en_US
dc.identifier.wosWOS:000287982000051
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofEnvironmental Monitoring and Assessmenten_US
dc.relation.journalEnvironmental Monitoring and Assessmenten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAmberlite XAD-4en_US
dc.subjectFAASen_US
dc.subjectN,N-Bis(salicylidene)cyclohexanediamine (SCHD)en_US
dc.subjectPreconcentrationen_US
dc.subjectSchiff's Baseen_US
dc.subjectSolid Phase Extractionen_US
dc.titleSolid Phase Extraction and Preconcentration of Cu(II), Pb(II), and Ni(II) in Environmental Samples on Chemically Modified Amberlite XAD-4 With a Proper Schiff Baseen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files