Publication:
The Influence of Determining the Working Length with an Apex Locator on the Amount of Apically Extruded Debris Following Instrumentation with ProTaper Next and HyFlex CM

dc.authorscopusid56221938900
dc.authorscopusid59130436600
dc.authorscopusid57063386700
dc.contributor.authorÇiçek, E.
dc.contributor.authorYilmaz, N.
dc.contributor.authorFuruncuoǧlu, F.
dc.date.accessioned2020-06-21T09:42:25Z
dc.date.available2020-06-21T09:42:25Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Çiçek] Ersan, Department of Endodontics, Zonguldak Bulent Ecevit University, Zonguldak, Zonguldak, Turkey; [Yilmaz] Neslihan, Department of Endodontics, Zonguldak Bulent Ecevit University, Zonguldak, Zonguldak, Turkey; [Furuncuoǧlu] Fatma, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractAim: The amount of apically extruded debris caused by new nickel-titanium rotary systems after determination of the working length (WL) with an apex locator has not been investigated. To compare the amount of apically extruded debris with ProTaper Next (PTN) and HyFlex CM systems after determination of WL with/without an apex locator. Materials and Methods: Forty-eight extracted mandibular incisor teeth divided into four groups were used in this study. In Groups 1 and 2, a 10 K-file was progressed until it was just visible at the major apical foramen and WL was recorded as 1 mm short. In Groups 3 and 4, the WL was determined with the Root ZX (sensitivity of 0.1) using a 10 K-file. During the instrumentation, the PTN was used to X2 in groups 1 and 3, and the HyFlex CM was used to 25/.06 in groups 2 and 4. Distilled water was used as an irrigant. Debris was collected in tubes then stored in an incubator at 68°C for 5 days to evaporate the distilled water. The Eppendorf tubes, including the extruded debris, were weighed to obtain final weights. The amount of extruded debris was calculated by subtracting the weight of the empty tube from the weight of the dry tube. Data were analyzed by Kruskal-Wallis and Mann-Whitney U-test. Results: Less apically extruded debris was obtained in Group 3, with a significant difference compared to Group 1 and Group 2 (P < 0.05). Conclusions: The usage of apex locator to determine the WL decreased the amount of apically extruded debris. In addition, PTN caused less apical debris extrusion after determination WL with/without apex locator.en_US
dc.identifier.doi10.4103/1658-5984.189356
dc.identifier.endpage126en_US
dc.identifier.issn2278-9618
dc.identifier.issn2320-1495
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-84985991511
dc.identifier.scopusqualityQ3
dc.identifier.startpage122en_US
dc.identifier.urihttps://doi.org/10.4103/1658-5984.189356
dc.identifier.volume6en_US
dc.language.isoenen_US
dc.publisherMedknow Publications B9, Kanara Business Centre, off Link Road, Ghatkopar (E) Mumbai 400 075en_US
dc.relation.ispartofSaudi Endodontic Journalen_US
dc.relation.journalSaudi Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectApex Locatoren_US
dc.subjectApical Debris Extrusionen_US
dc.subjectEndodonticsen_US
dc.subjectInstrumentationen_US
dc.subjectNickel-Titanium Instrumentsen_US
dc.titleThe Influence of Determining the Working Length with an Apex Locator on the Amount of Apically Extruded Debris Following Instrumentation with ProTaper Next and HyFlex CMen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files