Publication:
Biomechanical Comparison of Transoral and Transbuccal Lateral Cortical Plate Fixation for the Management of Mandibular Angle Fractures

dc.authorscopusid35995742400
dc.authorscopusid55346987600
dc.authorscopusid56702230500
dc.authorscopusid6603033336
dc.authorscopusid57200255486
dc.authorscopusid35791875600
dc.contributor.authorÖmezli, M.M.
dc.contributor.authorAyranci, F.
dc.contributor.authorPolat, M.
dc.contributor.authorDayi, E.
dc.contributor.authorGhahramanzadehasl, H.
dc.contributor.authorKaragöl, S.
dc.date.accessioned2020-06-21T13:17:53Z
dc.date.available2020-06-21T13:17:53Z
dc.date.issued2017
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ömezli] Mehmet Melih, Department of Oral and Maxillofacial Surgery, Ordu Üniversitesi, Ordu, Turkey; [Ayranci] Ferhat, Department of Oral and Maxillofacial Surgery, Ordu Üniversitesi, Ordu, Turkey; [Polat] Mehmet Emrah,; [Dayi] Ertunç,; [Ghahramanzadehasl] H., Department of Mechanical Engineering, Atatürk Üniversitesi, Erzurum, Erzurum, Turkey; [Karagöl] Serap, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractObjectives: The purpose of this experimental study was to compare the biomechanical behaviors of two different types of osteosynthesis that are used in the treatment of mandibular angle fractures. Materials and Methods: Twenty synthetic polyurethane human mandible replicas, with medullar and cortical portions, were used in this study. These polyurethane hemimandibles were randomly divided into two groups (n = 10). The transbuccal group (Group A) was fixed with 7 mm long self-tapping 2.0 mm titanium screws at 85° to the reference line and the transoral group (Group B) was fixed with the same screws at 15° to the reference line. All testings were performed on a servo-hydraulic testing machine. The data were transmitted directly from the load cell to a computer, which showed the emergent results of the material characteristics under resisted forces as a graphic containing force and displacement. The peak point loading and displacement for each subject were measured. Results: The comparison between the groups was analyzed with an independent-samples t-test, and P < 0.05 was considered to be significant. The results show that there were no significant differences between the groups for the peak loads and displacement values at the peak loads. Conclusion: The results of this experimental study demonstrated that there were no significant differences between the transbuccal and transoral methods in terms of fixation stability. In other words, the screw position and angle seemed to no have influence on the fixation stability in single miniplate treatments of a mandibular angle fracture. © 2018 Nigerian Journal of Clinical Practice | Published by Wolters Kluwer-Medknow.en_US
dc.identifier.doi10.4103/1119-3077.187319
dc.identifier.endpage1438en_US
dc.identifier.issn1119-3077
dc.identifier.issue11en_US
dc.identifier.pmid29303128
dc.identifier.scopus2-s2.0-85040527819
dc.identifier.scopusqualityQ2
dc.identifier.startpage1434en_US
dc.identifier.urihttps://doi.org/10.4103/1119-3077.187319
dc.identifier.volume20en_US
dc.identifier.wosWOS:000422772500009
dc.identifier.wosqualityQ3
dc.language.isoenen_US
dc.publisherMedknow Publications B9, Kanara Business Centre, off Link Road, Ghatkopar (E) Mumbai 400 075en_US
dc.relation.ispartofNigerian Journal of Clinical Practiceen_US
dc.relation.journalNigerian Journal of Clinical Practiceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMiniplate Fixationen_US
dc.subjectStabilityen_US
dc.subjectTransbuccalen_US
dc.titleBiomechanical Comparison of Transoral and Transbuccal Lateral Cortical Plate Fixation for the Management of Mandibular Angle Fracturesen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files