Publication:
Comparison of Culture, Real-Time DNA Amplification Assay and Ehrlich-Ziehl for Detection of Mycobacterium Tuberculosis

dc.authorscopusid55255630700
dc.authorscopusid55646053100
dc.authorscopusid24829334600
dc.authorscopusid35731277700
dc.authorscopusid7003851303
dc.authorscopusid16746539800
dc.contributor.authorKaradaǧ, A.
dc.contributor.authorUsta, E.
dc.contributor.authorBilgin, K.
dc.contributor.authorGüney, A.K.
dc.contributor.authorEroǧlu, C.
dc.contributor.authorGünaydin, M.
dc.date.accessioned2020-06-21T14:06:25Z
dc.date.available2020-06-21T14:06:25Z
dc.date.issued2013
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Karadaǧ] Adil, Department of Medical Microbiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Usta] Egemen, Department of Medical Microbiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Bilgin] Kemal, Department of Medical Services and Techniques, Vacational Higher School of Health Services, Samsun, Turkey; [Güney] Akif Koray, Department of Medical Microbiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Eroǧlu] Cafer, Department of Medical Microbiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Günaydin] Murat, Department of Medical Microbiology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractObjective: Mycobacterium tuberculosis is still a substantial health problem universally. Although culture is the gold standard method, reliable, rapid and new methods are required for effective struggle with disease. We retrospectively compared the results of Ehrlich-Ziehl-Neelsen (EZN) stain and real-time DNA amplification assay (BD ProbeTec ET system) with culture. Study Design: Retrospective study. Material and Methods: A total of 703 samples, 182 pulmonary and 521 extra pulmonary, collected from 630 patients between May 2008 and February 2011 were evaluated. Culture was considered the gold standard. Results: For pulmonary specimens, sensitivity, specificity, positive predictive and negative predictive values of BD ProbeTec ET and EZN were calculated to be 100%, 98.8%, 87.5%, 100% and 71.4%, 98.8%, 83.3%, 97.6%, respectively. For extra pulmonary specimens, sensitivity, specificity, positive predictive and negative predictive values of BD ProbeTec ET and EZN were calculated to be 80%, 98.7%, 76.9%, 98.9% and 24%, 98.3%, 42.8%, 96.2%, respectively. Conclusion: According to these results, we suggest that the BD ProbeTec ET system is more reliable than EZN. In addition, the BD ProbeTec ET system produces faster results. Based upon these results, we consider that the BD ProbeTec ET system may be employed in the diagnosis of M. tuberculosis. © Trakya University Faculty of Medicine.en_US
dc.identifier.doi10.5152/balkanmedj.2012.061
dc.identifier.endpage15en_US
dc.identifier.issn2146-3123
dc.identifier.issn2146-3131
dc.identifier.issue1en_US
dc.identifier.pmid25207061
dc.identifier.scopus2-s2.0-84875987419
dc.identifier.scopusqualityQ1
dc.identifier.startpage13en_US
dc.identifier.urihttps://doi.org/10.5152/balkanmedj.2012.061
dc.identifier.volume30en_US
dc.identifier.wosWOS:000317543300005
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherGalenos Publishing Houseen_US
dc.relation.ispartofBalkan Medical Journalen_US
dc.relation.journalBalkan Medical Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBD ProbeTec ETen_US
dc.subjectCultureen_US
dc.subjectMycobacterium Tuberculosisen_US
dc.titleComparison of Culture, Real-Time DNA Amplification Assay and Ehrlich-Ziehl for Detection of Mycobacterium Tuberculosisen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files