Publication:
Effects of Dimension Reduction in Mammograms Classification

dc.authorscopusid36976051300
dc.authorscopusid57200000622
dc.contributor.authorOral, C.
dc.contributor.authorSezgin, H.
dc.date.accessioned2020-06-21T14:16:30Z
dc.date.available2020-06-21T14:16:30Z
dc.date.issued2013
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Oral] Canan, Department of Electrical and Electronic Engineering, Amasya Üniversitesi, Amasya, Turkey; [Sezgin] Hatice, Department of Electrical and Electronic Engineering, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractBreast cancer is the most common type of cancer among women and causing deaths in women. In this paper, a CAD system is presented to investigate effects of dimension reduction for classifying mammograms. Proposed system consists of preprocessing, feature extraction, dimension reduction and classification steps. Multiscale top-hat transform is used to enhance mammograms and to remove noise. First order and second order textural features are extracted from enhanced mammograms. Principal component analysis (PCA) is used for dimension reduction. Two multilayer perceptron neural networks (MLP) are used to classify mammograms as normal or abnormal. All twenty features (without PCA) and selected seven features by PCA are applied each of two classifiers. First MLP classifier with all features achieved accuracy of 79,4%. Second MLP classifier with selected features by PCA achieved accuracy of 91,1%. PCA feature dimension reduction improved the classification performance, increasing accuracy value from 79,4% to 91,1%. © 2013 The Chamber of Turkish Electrical Engineers-Bursa.en_US
dc.identifier.doi10.1109/eleco.2013.6713912
dc.identifier.endpage633en_US
dc.identifier.isbn9786050105049
dc.identifier.scopus2-s2.0-84894152102
dc.identifier.startpage630en_US
dc.identifier.urihttps://doi.org/10.1109/eleco.2013.6713912
dc.identifier.wosWOS:000333752200135
dc.language.isoenen_US
dc.publisherIEEE Computer Society help@computer.orgen_US
dc.relation.ispartof-- 8th International Conference on Electrical and Electronics Engineering, ELECO 2013en_US
dc.relation.journal2013 8Th International Conference on Electrical and Electronics Engineering (Eleco)en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEffects of Dimension Reduction in Mammograms Classificationen_US
dc.typeConference Objecten_US
dspace.entity.typePublication

Files