Publication:
Effect of Pre-Heating on Color Stability of Resin Composites

dc.authorscopusid35310125300
dc.authorscopusid26021842100
dc.contributor.authorGönülol, N.
dc.contributor.authorKaraman, E.
dc.date.accessioned2020-06-21T09:42:07Z
dc.date.available2020-06-21T09:42:07Z
dc.date.issued2013
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Gönülol] Nihan, Dis Hekimligi Fakultesi, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Karaman] Emel, Dis Hekimligi Fakultesi, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractObjectives: The aim of this in vitro study was to evaluate the affect of pre-heating on color stability of a microhybrid composite resin Materials and Methods: In this study an A1 shade microhybrid resin composite (Filtek Z250, 3M ESPE) was used after storage in 4 different temperatures (4°C, 23 °C, 37 °C, 55 °C). Forty discshaped specimens were prepared in a teflon mold with a diameter of 10 mm and a depth of 2 mm (n=10). In the first group the specimens were stored in refrigerator at 4 °C and the 2nd group were kept in room temprature at 23 °C. In the 3rd and 4th groups a composite warmer (Micerium, S.p.a., Avegno GE, Italy) were used for heating the tubes up to 37 °C and 55 °C, respectively. The specimens were light cured for 40 s with a quarts tungsten halogen curing unit (Smart-Lite, Benlioglu Dental, Ankara, Turkey). The baseline and after 48 hours storage in the coffee solution (Nescafe Classic) the color measurements of the specimens were detected with Vita Easy-Shade digital colorimeter device and δE were calculated. The data were analysed with parametric one-way ANOVA and Tukey HSD tests. Results: The composite group pre-heated to 37 °C and 55 °C showed significantly lower δE values than the groups at 4 °C ve 23 °C (p<0.01). Conclusion: Pre-heating of the microhibrit composite caused lower discoloration.en_US
dc.identifier.doi10.7126/cdj.2013.1813
dc.identifier.endpage115en_US
dc.identifier.issn2146-2852
dc.identifier.issue2en_US
dc.identifier.scopus2-s2.0-84879485765
dc.identifier.scopusqualityQ4
dc.identifier.startpage110en_US
dc.identifier.urihttps://doi.org/10.7126/cdj.2013.1813
dc.identifier.volume16en_US
dc.language.isotren_US
dc.relation.ispartofCumhuriyet Dental Journalen_US
dc.relation.journalCumhuriyet Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectColor Stabilityen_US
dc.subjectComposite Resinsen_US
dc.subjectPre-Heatingen_US
dc.titleEffect of Pre-Heating on Color Stability of Resin Compositesen_US
dc.title.alternativePolimerizasyon Öncesi Isıtma İşleminin Kompozit Rezinlerde Renk Değişimine Etkisien_US
dc.typeArticleen_US
dspace.entity.typePublication

Files