Cyclic Fatigue Resistance of XP-Endo Shaper, K3XF, and ProTaper Gold Nickel-Titanium Instruments

dc.authorscopusid56471565700
dc.authorscopusid22934205900
dc.authorscopusid42561320300
dc.authorscopusid35784439500
dc.contributor.authorKeskin, C.
dc.contributor.authorInan, U.
dc.contributor.authorGüler, D.H.
dc.contributor.authorKalyoncuoǧlu, E.
dc.date.accessioned2020-06-21T13:10:56Z
dc.date.available2020-06-21T13:10:56Z
dc.date.issued2018
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Keskin] Cangül, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Inan] Uǧur, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Güler] Duygu H., Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Kalyoncuoǧlu] Elif, Department of Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractIntroduction: The aim of this study was to compare the cyclic fatigue resistance of the ProTaper Gold (PTG; Dentsply Maillefer, Ballaigues, Switzerland), K3XF (SybronEndo, Orange, CA), and XP-endo Shaper (FKG Dentaire, La Chaux-de-Fond, Switzerland) nickel-titanium rotary instruments at intracanal temperatures. Methods: Eighteen XP-endo Shaper (30.01), 18 K3XF (30.04), and 18 PTG F3 (30.09v) instruments were used to test the cyclic fatigue resistance at an intracanal temperature of 35° ± 2°C. The instruments were tested in a metal block that simulated a canal curvature angle of 60° and a curvature or radius of 5 mm. All instruments were operated until fracture occurred, and then the number of cycles to failure was calculated. The lengths of fractured fragments were measured with a digital caliper. The data were analyzed statistically using 1-way analysis of variance and the Tukey post hoc test with significance set at P <.05. Results: The XP-endo Shaper instruments showed a significantly higher number of cycles to fracture than the K3XF and PTG instruments (P <.05). There was no difference between the PTG and K3XF instruments (P >.05). Conclusions: The XP-endo Shaper instruments exhibited greater cyclic fatigue resistance compared with the other instruments at the intracanal temperature. © 2018 American Association of Endodontistsen_US
dc.identifier.doi10.1016/j.joen.2018.04.005
dc.identifier.endpage1167en_US
dc.identifier.issn0099-2399
dc.identifier.issn1878-3554
dc.identifier.issue7en_US
dc.identifier.pmid29866409
dc.identifier.scopus2-s2.0-85048718024
dc.identifier.scopusqualityQ1
dc.identifier.startpage1164en_US
dc.identifier.urihttps://doi.org/10.1016/j.joen.2018.04.005
dc.identifier.volume44en_US
dc.identifier.wosWOS:000437818800016
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherElsevier Inc. usjcs@elsevier.comen_US
dc.relation.ispartofJournal of Endodonticsen_US
dc.relation.journalJournal of Endodonticsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectIntracanal Temperatureen_US
dc.subjectNickel-Titaniumen_US
dc.subjectStatic Cyclic Fatigue Deviceen_US
dc.titleCyclic Fatigue Resistance of XP-Endo Shaper, K3XF, and ProTaper Gold Nickel-Titanium Instrumentsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files