Publication: All-Solid-State PVC Membrane Ag+-Selective Electrodes Based on Diaza-18-Crown-6 Compounds
| dc.contributor.author | Isildak, I | |
| dc.contributor.author | Yolcu, M | |
| dc.contributor.author | Isildak, O | |
| dc.contributor.author | Demirel, N | |
| dc.contributor.author | Topal, G | |
| dc.contributor.author | Hosgoren, H | |
| dc.contributor.authorID | YOLCU, Murat/0000-0003-3477-3792 | |
| dc.date.accessioned | 2020-06-21T15:43:32Z | |
| dc.date.available | 2020-06-21T15:43:32Z | |
| dc.date.issued | 2004 | |
| dc.department | OMÜ | en_US |
| dc.department-temp | Ondokuz Mayis Univ, Fac Sci, Dept Chem, TR-55139 Kurupelit, Turkey -- Gaziosmanpasa Univ, Fac Sci, Dept Chem, TR-60200 Tokat, Turkey -- Dicle Univ, Fac Sci, Dept Chem, TR-21280 Diyarbakir, Turkey -- Dicle Univ, Fac Educ, Dept Chem, TR-21280 Diyarbakir, Turkey -- | en_US |
| dc.description.abstract | Two diaza-crown ether compounds were synthesized and evaluated as Ag+-selective carriers in polyvinylchloride (PVC) membrane electrodes of solid-state type. The all-solid-state PVC membrane electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 exhibited a super-Nernstian response (75+/-10 mV per decade) over the concentration range of 1x10(-1) to 7x10(-6) M of Ag+ ion and a detection limit of 3x10(-6) M, at a wide range of pH (pH 4-7). The response time of the electrode was fast (less than similar to10s), and it can be used for three months without any significant deviation in potential. The proposed all-solid-state PVC membrane electrodes revealed high selectivity toward Ag+ ion with respect to alkali, alkaline earth, heavy and transition metal ions. A flow-through cell of all-solid-state PVC membrane Ag+-selective electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 has also been prepared and applied for flow-injection analysis of Ag+ ion in solution. | en_US |
| dc.identifier.doi | 10.1007/s00604-003-0072-7 | |
| dc.identifier.endpage | 181 | en_US |
| dc.identifier.issn | 1436-5073 | |
| dc.identifier.startpage | 177 | en_US |
| dc.identifier.uri | https://doi.org/10.1007/s00604-003-0072-7 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/21649 | |
| dc.identifier.volume | 144 | en_US |
| dc.identifier.wos | WOS:000188300100026 | |
| dc.language.iso | en | en_US |
| dc.publisher | Springer-Verlag Wien | en_US |
| dc.relation.journal | Microchimica Acta | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Diaza-Crown Ethers | en_US |
| dc.subject | All-Solid-State | en_US |
| dc.subject | PVC Membrane | en_US |
| dc.subject | Silver-Selective Electrodes | en_US |
| dc.subject | FIA | en_US |
| dc.title | All-Solid-State PVC Membrane Ag+-Selective Electrodes Based on Diaza-18-Crown-6 Compounds | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
