Publication:
Influence of Implant Abutment Material on the Color of Different Ceramic Crown Systems

dc.authorscopusid36245912800
dc.authorscopusid55920051300
dc.authorscopusid6506600649
dc.authorscopusid56156696200
dc.authorscopusid23988464900
dc.authorscopusid35583824600
dc.contributor.authorÖmür Dede, D.Ö.
dc.contributor.authorArmağanci, A.
dc.contributor.authorCeylan, G.
dc.contributor.authorÇelik, E.
dc.contributor.authorÇankaya, S.
dc.contributor.authorYilmaz, B.
dc.date.accessioned2020-06-21T13:31:52Z
dc.date.available2020-06-21T13:31:52Z
dc.date.issued2016
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Ömür Dede] Doğu Ömür, Department of Prosthodontics, Ordu Üniversitesi, Ordu, Turkey; [Armağanci] Arzu, Samsun Public Oral Health Center, Practitioner, Samsun, Turkey; [Ceylan] Gözlem Koca, Department of Prosthodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Çelik] Ersan, Department of Prosthodontics, Ordu Üniversitesi, Ordu, Turkey; [Çankaya] Soner, Department of Biostatistics, Ordu Üniversitesi, Ordu, Turkey; [Yilmaz] Burak, College of Dentistry, The Ohio State University, Columbus, OH, United Statesen_US
dc.description.abstractStatement of problem Ceramics are widely used for anterior restorations; however, clinical color reproduction still constitutes a challenge particularly when the ceramic crowns are used on titanium implant abutments. Purpose The purpose of this in vitro study was to investigate the effect of implant abutment material on the color of different ceramic material systems. Material and methods Forty disks (11×1.5 mm, shade A2) were fabricated from medium-opacity (mo) and high-translucency (ht) lithium disilicate (IPS e.max) blocks, an aluminous ceramic (VITA In-Ceram Alumina), and a zirconia (Zirkonzahn) ceramic system. Disks were fabricated to represent 3 different implant abutments (zirconia, gold-palladium, and titanium) and dentin (composite resin, A2 shade) as background (11×2 mm). Disk-shaped composite resin specimens in A2 shade were fabricated to represent the cement layer. The color measurements of ceramic specimens were made on composite resin abutment materials using a spectrophotometer. CIELab color coordinates were recorded, and the color coordinates measured on composite resin background served as the control group. Color differences (ΔE<inf>00</inf>) between the control and test groups were calculated. The data were analyzed with 2-way analysis of variance (ANOVA) and compared with the Tukey HSD test (α=.05). Results The ceramics system, abutment material, and their interaction were significant for ΔE<inf>00</inf> values (P<.001). Clinically unacceptable results (ΔE<inf>00</inf>>2.25) were observed for lithium disilicate ceramics on titanium abutments (2.46-2.50). The ΔE<inf>00</inf> values of lithium disilicate ceramics for gold-palladium and titanium abutments were significantly higher than for other groups (P<.05). Conclusion The color results (ΔE<inf>00</inf>>2.25) of an implant-supported lithium disilicate ceramic restoration may be clinically unacceptable if it is fabricated over a titanium abutment. Zirconia may be a more suitable abutment material for implant-supported ceramic restorations. © 2016 Editorial Council for the Journal of Prosthetic Dentistryen_US
dc.identifier.doi10.1016/j.prosdent.2016.04.004
dc.identifier.endpage769en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue5en_US
dc.identifier.pmid27402418
dc.identifier.scopus2-s2.0-84992724598
dc.identifier.scopusqualityQ1
dc.identifier.startpage764en_US
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2016.04.004
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13031
dc.identifier.volume116en_US
dc.identifier.wosWOS:000387302400010
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherMosby Inc. customerservice@mosby.comen_US
dc.relation.ispartofJournal of Prosthetic Dentistryen_US
dc.relation.journalJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleInfluence of Implant Abutment Material on the Color of Different Ceramic Crown Systemsen_US
dc.typeConference Objecten_US
dspace.entity.typePublication

Files