Publication:
Myocardial Perfusion Imaging: Pitfalls and Artifacts

dc.authorscopusid11141188900
dc.authorscopusid59006292900
dc.authorscopusid6602757748
dc.contributor.authorSemirgin, Sibel Uçak
dc.contributor.authorAlgül, G.İ.
dc.contributor.authorCanbaz, F.C.
dc.date.accessioned2025-12-11T00:33:35Z
dc.date.issued2024
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Semirgin] Sibel Uçak, Nükleer Tıp Anabilim Dalı, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Algül] Gamze İrem, Nükleer Tıp Anabilim Dalı, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Canbaz] Fevziye, Nükleer Tıp Anabilim Dalı, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractMyocardial perfusion scintigraphy has long been utilized as a non-invasive imaging modality for the clinical assessment of coronary artery disease. This technique involves the assessment of myocardial cell perfusion by evaluating images obtained following the injection of radiopharmaceuticals, allowing for the identification of ischemic or infarcted areas. Additionally, it provides the opportunity to assess parameters such as wall motion and thickening through images synchronized with electrocardiography. Due to the complex physiological processes reflected in the myocardium by this imaging technique, it encompasses a range of potential pitfalls and artifacts that could lead to misinterpretations, resulting in false-positive or false-negative evaluations. Therefore, it is imperative that the entire team involved in both the preparation of patients and the imaging process possesses knowledge to anticipate, preferably prevent, or rectify potential issues. This review aims to discuss pitfalls and artifacts that may arise at various stages of myocardial perfusion scintigraphy, potentially leading to misinterpretations of the examination. Furthermore, it provides insights into precautions that should be taken and potential solutions when possible. © 2024 Galenos Publishing House. All rights reserved.en_US
dc.identifier.doi10.4274/NTS.GALENOS.2024.0006
dc.identifier.endpage80en_US
dc.identifier.issn2149-6447
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-85191599158
dc.identifier.scopusqualityQ4
dc.identifier.startpage62en_US
dc.identifier.urihttps://doi.org/10.4274/NTS.GALENOS.2024.0006
dc.identifier.urihttps://hdl.handle.net/20.500.12712/37427
dc.identifier.volume10en_US
dc.language.isotren_US
dc.publisherGalenos Publishing Houseen_US
dc.relation.ispartofNuclear Medicine Seminarsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectArtifactsen_US
dc.subjectCardiac Imagingen_US
dc.subjectMyocardial Perfusion Scintigraphyen_US
dc.subjectSPECTen_US
dc.titleMyocardial Perfusion Imaging: Pitfalls and Artifactsen_US
dc.title.alternativeMiyokart Perfüzyon Sintigrafisi: Tuzak Ve Artefaktlaren_US
dc.typeArticleen_US
dspace.entity.typePublication

Files