Publication:
Kullanıcı Deneyiminin Farklı Teknolojilerle Üretilen Döner Nikel-titanyum Tek Eğe Sistemlerinin Döngüsel Yorgunluğu Üzerindeki Etkisi

dc.contributor.advisorTunga, Umut
dc.contributor.authorYalçın, Oğuzhan
dc.date.accessioned2025-12-13T09:27:05Z
dc.date.issued2020
dc.departmentDiş Hekimliği Fakültesi / Endodonti Ana Bilim Dalı
dc.description.abstractAmaç: Kullanıcı deneyiminin farklı teknolojilerle üretilmiş döner nikel-titanyum eğe sistemlerinin döngüsel yorgunlukları üzerindeki etkisini değerlendirmektir. Materyal ve Metot: Döner NiTi eğeler ile kök kanal preparasyonu deneyimi olmayan klinik staj öğrencisi (grup 1), lisansüstü düzeyde endodonti eğitimi almakta olan araştırma görevlileri (grup 2) ve endodonti uzmanları (grup 3) olmak üzere 10'ar kişilik üç farklı grup oluşturuldu. Her bir operatör 1 adet WaveOne Gold Primary (Dentsply Maillefer, İsviçre) ve 1 adet Hyflex EDM Onefile (Coltene, İsviçre) döner sistem NiTi eğesi kullanmak üzere çalışmada toplam da 80 adet döner sistem NiTi eğesi kullanıldı. Her eğe farklı deneyime sahip operatör tarafından tek sefer rezin blokta bulunan kurvatürlü yapay kanalın preperasyonunda kullanıldıktan sonra eğeler, 60 ° 'lik kurvatür açısı ve 5 mm'lik kanal kurvatür çapına sahip yapay kanalı olan metal bloklarda kırılıncaya kadar döndürüldü. Döngüsel yorgunluk test işlemi vücut sıcaklığında gerçekleştirildi. Kırık tipinin belirlenmesi için eğelerin kırılma yüzeylerinden taramalı elektron mikroskobu (SEM) altında fotomikrografiler alındı. Elde edilen verilere uygun istatistiksel analizler yapıldı. Bulgular: Deneyim düzeylerine göre ayırılan kullanıcı grupları arasında her iki eğe grubunda da istatistiksel olarak anlamlı bir fark görülememiştir (P < 0, 05). Herhangi bir preparasyon işleminde kullanılmadan döngüsel yorgunluk testi yapılan kontrol grubu her iki eğe türünde de tüm kullanıcı gruplarına göre daha yüksek yorgunluk direnci göstermiştir. Hyflex EDM, WaveOne Gold'a göre tüm gruplarda daha yüksek yorgunluk dayanımı göstermiştir (P < 0, 05). Sonuç: Kullanıcı deneyiminin eğelerin döngüsel yorgunluğu üzerine etkisi bulunamamıştır.
dc.description.abstractAim: The present study aimed to evaluate the effect of operator experience on cyclic fatigue of rotary nickel-titanium file systems produced with different technologies. Material and Methods: Three different experience groups of 10 people were formed. These are: clinical internship student without experience in root canal preparation with rotary NiTi files (group 1), research assistants receiving postgraduate endodontics education (group 2) and endodontics specialists (group 3). Each operator used 1 WaveOne Gold Primary (Dentsply Maillefer, Switzerland) and 1 Hyflex EDM Onefile (Coltene, Switzerland) rotary system NiTi file. A total of 80 rotary system NiTi files were used. After each file was used by the operator who have different experience in the preparation of the artificial curved root canal in the resin block, the files were rotated until they were broken in metal blocks with a 60 ° curvature angle and 5 mm canal curvature diameter. The test was carried out at body temperature. The fracture surfaces of the file to determine the type of fracture scanning electron microscope (SEM) photomicrographs were taken under. Data were statistically analyzed. Results: There was no statistically significant difference between the operator groups separated by experience levels in both file groups (P <0, 05). The control group which underwent cyclic fatigue testing without using any preparation process showed higher fatigue resistance in both file types compared to all operator groups. Hyflex EDM showed higher fatigue resistance in all groups than WaveOne Gold (P <0.05). Conclusion: No effect of operator experience on cyclic fatigue of files was found.en_US
dc.identifier.endpage80
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=_F5QEpayDXGqGZlp9XiFtDRdTbz97Vsunkz7tE4uH8cHgAO4o0Y0zAXtrPvfvaLl
dc.identifier.urihttps://hdl.handle.net/20.500.12712/51525
dc.identifier.yoktezid630803
dc.language.isotr
dc.subjectDiş Hekimliği
dc.subjectDeneyim
dc.subjectDental Aygıtlar
dc.subjectKullanıcı
dc.subjectKullanıcı Deneyimi
dc.subjectMetal Yorgunluğu
dc.subjectDentistryen_US
dc.subjectExperienceen_US
dc.subjectDental Instrumentsen_US
dc.subjectUseren_US
dc.subjectUser Experienceen_US
dc.subjectMetal Fatigueen_US
dc.titleKullanıcı Deneyiminin Farklı Teknolojilerle Üretilen Döner Nikel-titanyum Tek Eğe Sistemlerinin Döngüsel Yorgunluğu Üzerindeki Etkisi
dc.titleThe Effect of the Operator Experience on Cyclic Fatigue of Rotating Nickel-Titanium Single File Systems Produced With Different Technologiesen_US
dc.typeSpecialist Thesisen_US
dspace.entity.typePublication

Files