Publication: Scleral Fixation of a Single-Piece Multifocal Intraocular Lens
| dc.authorscopusid | 55125592200 | |
| dc.authorscopusid | 55603643800 | |
| dc.authorscopusid | 25723204700 | |
| dc.contributor.author | Can, E. | |
| dc.contributor.author | Reşat Başaran, M. | |
| dc.contributor.author | Gül, A. | |
| dc.date.accessioned | 2020-06-21T14:06:14Z | |
| dc.date.available | 2020-06-21T14:06:14Z | |
| dc.date.issued | 2013 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Can] Ertugrul, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Reşat Başaran] M., Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Gül] Adem, Department of Ophthalmology, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | Purpose. We describe an ab interno technique for injector implantation of a one-piece multifocal intraocular lens (IOL). Methods. Transscleral fixation of multifocal posterior chamber IOL implantation using an injector with ab interno technique was performed in an eye of a 9-year-old girl who had undergone pars plana lensectomy 2 years before for bilateral lens subluxation with unknown etiology. Results. No major complications were encountered during a 3-month follow-up of the patient and excellent centration was observed during the follow-up period. Her preoperative best spectaclecorrected distance visual acuity of 20/32 improved to uncorrected distance visual acuity of 20/25. Conclusions. Closed-loop design of IOL served the function of eyelets and position of the IOL was provided using only a 2-point fixation. Intraoperative position adjustment of the IOL provided an excellent centralization of multifocal IOL. © 2013 Wichtig Editore. | en_US |
| dc.identifier.doi | 10.5301/ejo.5000225 | |
| dc.identifier.endpage | 251 | en_US |
| dc.identifier.issn | 1120-6721 | |
| dc.identifier.issn | 1724-6016 | |
| dc.identifier.issue | 2 | en_US |
| dc.identifier.pmid | 23335307 | |
| dc.identifier.scopus | 2-s2.0-84874176549 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 249 | en_US |
| dc.identifier.uri | https://doi.org/10.5301/ejo.5000225 | |
| dc.identifier.volume | 23 | en_US |
| dc.identifier.wos | WOS:000324918700017 | |
| dc.identifier.wosquality | Q3 | |
| dc.language.iso | en | en_US |
| dc.publisher | Wichtig Editore | en_US |
| dc.relation.ispartof | European Journal of Ophthalmology | en_US |
| dc.relation.journal | European Journal of Ophthalmology | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Aphakia | en_US |
| dc.subject | Complication | en_US |
| dc.subject | Intraocular Lens | en_US |
| dc.subject | Multifocal | en_US |
| dc.subject | Scleral Fixation | en_US |
| dc.subject | Technique | en_US |
| dc.title | Scleral Fixation of a Single-Piece Multifocal Intraocular Lens | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
