Publication:
Detrimental Effects of Sterilization Types on Single-Use Coronary Angioplasty Catheters for Reuse: An Electron Microscopic Study

dc.authorwosidAtilla, Aynur/Lnr-0752-2024
dc.authorwosidOnger, Mehmet/Lfu-5422-2024
dc.contributor.authorKuruoglu, Tuba
dc.contributor.authorOnger, Mehmet Emin
dc.contributor.authorAltun, Gamze
dc.contributor.authorAtilla, Aynur
dc.contributor.authorEsen, Saban
dc.contributor.authorIDOnger, Mehmet Emin/0000-0001-8922-9642
dc.contributor.authorIDAltun, Gamze/0000-0003-3959-9893
dc.contributor.authorIDAtilla, Aynur/0000-0001-8027-1991
dc.contributor.authorIDKuruoglu, Tuba/0000-0003-3805-367X
dc.date.accessioned2025-12-11T01:32:57Z
dc.date.issued2024
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Kuruoglu, Tuba; Atilla, Aynur; Esen, Saban] Ondokuz Mayis Univ, Sch Med, Dept Clin Microbiol & Infect Dis, Samsun, Turkiye; [Onger, Mehmet Emin; Altun, Gamze] Ondokuz Mayis Univ, Sch Med, Dept Histol & Embryol, T0rkiye, Samsun, Turkiyeen_US
dc.descriptionOnger, Mehmet Emin/0000-0001-8922-9642; Altun, Gamze/0000-0003-3959-9893; Atilla, Aynur/0000-0001-8027-1991; Kuruoglu, Tuba/0000-0003-3805-367Xen_US
dc.description.abstractObjective: Reuse of medical devices poses risks concerning technical issues and patient safety. In this study, we aimed to examine the structural changes in catheters that occur due to the reuse with the aid of electron microscopy. Materials and Methods: The effects of hydrogen peroxide (HP) and ethylene oxide (EO) sterilization on four percutaneous transluminal coronary angioplasty (PTCA) catheters and control PTCA catheters were examined by scanning electron microscope (SEM). Each catheter sample was divided into four parts during the SEM examination, and a total of 20 pieces were examined. Catheters were reprocessed through every regular sterilization step and used solely for the study, not in patients. Statistical evaluations of histological scoring made on images obtained from scanning electron microscopic images were made using the GraphPad Prism 8 program. Results: Electron microscopical examination showed that HP sterilization caused more robust and deeper lines compared to EO. These distortions increased directly with the increase in the reprocessing cycle. In EO, no significant damage was detected within five cycles in contrast to HP; however, the harmful effects of EO were seen over five cycles. Unprocessed samples had no damage. Outer and inner deterioration was significantly higher in the EO>5 group and HP>5 group than in the control group. However, the bacterial contamination score in the EO>5 group was higher than the control group. Conclusion: Our findings showed that HP and EO sterilizations caused some deterioration in the inner and outer surfaces of PTCA catheter samples. We recommend reprocessing using EO, the least damaging method, when necessary, and paying attention not to exceed five cycles when necessary.en_US
dc.description.woscitationindexEmerging Sources Citation Index
dc.identifier.doi10.36519/idcm.2024.252.1
dc.identifier.endpage10en_US
dc.identifier.issn2667-646X
dc.identifier.issue1en_US
dc.identifier.pmid38633441
dc.identifier.startpage4en_US
dc.identifier.trdizinid1230450
dc.identifier.urihttps://doi.org/10.36519/idcm.2024.252.1
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/1230450/detrimental-effects-of-sterilization-types-on-single-use-coronary-angioplasty-catheters-for-reuse-an-electron-microscopic-study
dc.identifier.urihttps://hdl.handle.net/20.500.12712/44496
dc.identifier.volume6en_US
dc.identifier.wosWOS:001184606200001
dc.language.isoenen_US
dc.publisherDoc Design Informatics Co Ltden_US
dc.relation.ispartofInfectious Diseases and Clinical Microbiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectEthylene Oxideen_US
dc.subjectPercutaneous Transluminal Coronary Angioplastyen_US
dc.subjectScanning Electron Microscopyen_US
dc.subjectSingle-Use Instrumenten_US
dc.titleDetrimental Effects of Sterilization Types on Single-Use Coronary Angioplasty Catheters for Reuse: An Electron Microscopic Studyen_US
dc.typeArticleen_US