Publication: Comparison of Continuous Wave and Cold Lateral Condensation Filling Techniques in 3D Printed Simulated C-Shape Canals Instrumented With Reciproc Blue or Hyflex EDM
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Aim To compare the efficiency of continuous wave obturation and cold lateral condensation techniques and filling time in C-shape canals of 3-dimensional (3D)-printed resin teeth shaped with Reciproc Blue (VDW) or Hyflex EDM (Coltene/Whaledent). Methodology One tooth with C1-type orifice and root canal morphology and one with C2-type orifice and C2-C3 root canal morphology were selected based on CBCT. Two replicas of selected teeth were manufactured with a 3D-printer and their canals were instrumented with Reciproc Blue or Hyflex EDM. These 4 instrumented replicas were scanned with CBCT. Identical 10 replicas of each group (total of 40) were produced using a 3D-printer and randomly divided into 2 groups (n = 5), root filled with either continuous wave obturation (CW) or cold lateral condensation (LC). Horizontal cross-sections of C1-type were made at 2, 4, 6, 8 mm and C2-type at 2, 4, 6 mm from the apical foramen. Gutta-percha, sealer and void areas were evaluated with image analysis sofware. Data were analysed using nonparametric Kruskal-Wallis and Mann Whitney-U tests and the Factorial ANOVA was used for interaction effects. Time required to fill canals was evaluated using the Mann-Whitney U test. Results For C1-type, LC had more gutta-percha and less sealer compared to CW in 2-mm sections (p<0.05). CW had greater percentages of gutta-percha and lower percentages of sealer compared with LC group in 4, 6, 8 mm sections and total area (p<0.05). LC group had higher percentages of voids compared to CW group in 2 and 4 mm sections (p<0.05). For C2-type, CW had more gutta-percha and less sealer versus LC group in all sections and total area (p<0.05). LC had the least gutta-percha and greatest sealer percentages at 6-mm sections (p<0.05). There was no statistically significant difference in the percentages of voids at any level of sections between the filling techniques (p>0.05). In both C-types, there was no significant difference in the percentages of gutta-percha, sealer and voids between Reciproc Blue and Hyflex EDM-shaped groups at any level (p>0.05). Time spent for the LC technique and filling C1-type was significantly longer than when using the CW technique and filling C2-type (p<0.05). Conclusions Continuous wave obturation was more effective than lateral condensation in both C1- and C2-type, except for the apical 2 mm section of C1-type, suggesting the need for a modified CW technique. © 2019 Karatekin et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Description
Keywords
Citation
WoS Q
Q2
Scopus Q
Q1
Source
PLOS ONE
Volume
14
Issue
11
