dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Bayrak] Ilkay Koray, Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey, Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Özmen] Zafer C., Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Nural] Mehmet Selim, Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Danaci] Murat, Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Diren] Haldun Baris, Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractObjective: It has been advocated that a reduced injection volume with highly concentrated (1 M) contrast material can produce a sharper bolus peak and an increased intravascular first-pass gadolinium concentration when compared with the use of a lower concentration (0.5 M). A higher concentration would also cause a reduction in dose. The purpose of our study was to test the use of a low dose (0.05 mmol/kg) of gadobutrol in magnetic resonance renography and angiography and compare the findings with a dose of 0.1 mmol/kg. Materials and Methods: One-hundred-thirty-four patients referred for magnetic resonance angiography for suspected renovascular disease participated in the study. Contrast enhanced MR renography and angiography were performed after administration of a bolus of 0.1 mmol/kg or 0.05 mmol/kg gadobutrol in randomized patients. The relative signal intensity-time curves of the aorta, peripheral cortex and parenchyma, were obtained. Two radiologists evaluated the angiographic images and evaluated the quality of angiography. Results: The signal intensity with a low dose of gadobutrol was significantly lower in early phases, in the peripheral cortex (for 36, 54, 72 and 90 seconds), the parenchyma (for 36, 54, 72 seconds) and the aorta (for 18, 36, 54, 72 seconds). The decreases in the early phase obtained with a low dose of gadobutrol caused blunter time intensity curves. The difference in the quality scores of the readers for the angiographic images for the use of the two different doses was not statistically significant (p > 0.05). Conclusion: A lower dose of gadobutrol can be used for MR renal angiography, but for MR renography the normal dose should be used.en_US
dc.identifier.doi10.3348/kjr.2008.9.3.250
dc.identifier.endpage257en_US
dc.identifier.issn1229-6929
dc.identifier.issn2005-8330
dc.identifier.issue3en_US
dc.identifier.pmid18525228
dc.identifier.scopus2-s2.0-46849104105
dc.identifier.scopusqualityQ1
dc.identifier.startpage250en_US
dc.identifier.urihttps://doi.org/10.3348/kjr.2008.9.3.250
dc.identifier.volume9en_US
dc.identifier.wosWOS:000256676900009
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherKorean Radiological Socen_US
dc.relation.ispartofKorean Journal of Radiologyen_US
dc.relation.journalKorean Journal of Radiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAngiographyen_US
dc.subjectContrast Agent Angiographyen_US
dc.subjectFunctional Imagingen_US
dc.subjectGenitourinary Tracten_US
dc.subjectKidneyen_US
dc.subjectMagnetic Resonance (MR)en_US
dc.subjectRenographyen_US
dc.titleA Comparison of Low-Dose and Normal-Dose Gadobutrol in MR Renography and Renal Angiographyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files