Publication:
Farklı Braket Sistemlerinde Meydana Gelen Sürtünme Kuvvetlerinin Diş Hareketine Etkilerinin İncelenmesi

dc.contributor.advisorArıcı, Selim
dc.contributor.authorÖz, Abdullah Alper
dc.date.accessioned2020-07-21T21:59:25Z
dc.date.available2020-07-21T21:59:25Z
dc.date.issued2010
dc.departmentOMÜ, Sağlık Bilimleri Enstitüsü, Ortodonti Anabilim Dalıen_US
dc.departmentSağlık Bilimleri Enstitüsü / Ortodonti Ana Bilim Dalı
dc.descriptionTez (yüksek lisans) -- Ondokuz Mayıs Üniversitesi, 2010en_US
dc.descriptionLibra Kayıt No: 77597en_US
dc.description.abstractBu çalışmanın amacı kendinden bağlanabilen bir braket (SmartClip) ile modifiye edilmiş dizayna sahip bir braket (Mini Uni-Twin) arasında kayma mekaniği sırasındaki köpek diş hareketini ve oluşan sürtünme özelliklerini karşılaştırmaktır.19 hastada braketler split mouth dizayn kullanılarak yapıştırıldı. Bir taraftaki köpek dişine SC braketler yapıştırılırken diğer tarafta bulunan köpek dişine ise MUT braketler yapıştırıldı. Köpek dişi retraksiyonu 0,019x0,025 inch paslanmaz çelik teller üzerinde nikel titanyum yaylar ile 200 gr kuvvet uygulanarak gerçekleştirildi. Alınan yan kafa röntgenlerinde köpek ve büyük azı dişlerinin hareket miktarları referans teller kullanılarak ölçüldü. Ayrıca bir tribometer sürtünme test cihazı kullanılarak her iki braketin in vitro şartlar altında sergilediği sürtünme katsayıları ölçüldü.Üst çenede köpek dişlerinin hareket ve distal devrilme miktarı SC grubunda 1.83 mm, 5,15°, MUT grubunda ise 1,89 mm, 5,58°, alt çenede ise SC grubunda 1,79 mm, 3°, MUT grubunda ise 1,70 mm, 5,07° olarak bulundu. Sürtünme katsayısı (COF) ortalamaları MUT için 0,21 µ, SC için ise 0,37 µ' olarak ölçüldü.In vitro çalışmada her iki braketin COF değerleri arasında anlamlı bir fark tespit edilmiş olmasına rağmen, klinik veriler değerlendirildiğinde köpek diş hareket miktarı ve açılanmasında SC ve MUT braketi arasında anlamlı farklılık bulunamamıştır (P>0.05).
dc.description.abstractThe aim of this study was to compare the firctional properties and the rate of canine movement with sliding mechanics between a self-ligating brackets (SmartClip) and a modified twin design bracket (Mini Uni-Twin).A split mouth design was used for bonding the brackets of the nineteen patients. 0,022 inch slot canine SC brackets were bonded on one side and on the contralateral side 0,022 inch slot MUT brackets were used. Canine retraction was achieved on 0,019x0,025 inch stainless steel arch wires with nickel-titanium coil springs with a force level of 200 g. Lateral cephalometric radiographs with reference wires were taken and the measurements were analyzed on these records. A tribometer testing device was also used to measure the coefficient of friction of these two brackets in vitro conditions.In the maxilla, the canine moved and tipped distally 1.83 mm, 5,15° in the SC and 1,89 mm, 5,58° MUT. In the mandible the canine moved and tipped distally 1,79 mm, 3° in the SC, 1,70 mm, 5,07° in the MUT. The mean coefficient of friction (COF) was 0,21 µ for MUT and 0,37 µ for SC brackets.Although the COF values of two brackets were significantly different in vitro, there was no significant difference in the rate of canine movement and angulations amounts between SC and MUT (P>0.05) brackets in clinical study.en_US
dc.formatVI, 106 y. : tablo, şekil ; 30sm.en_US
dc.identifier.endpage115
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=veR1mHu9yoWjwcVUjCEoPKw47UNCPdkf0rRcnzi1VcdtaIjyYwHwYXAQSUju8ifB
dc.identifier.urihttp://libra.omu.edu.tr/tezler/77597.pdf
dc.identifier.urihttps://hdl.handle.net/20.500.12712/29050
dc.identifier.yoktezid272381
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Sağlık Bilimleri Enstitüsüen_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliği
dc.subjectDental Oklüzyon
dc.subjectDiş Hareketleri
dc.subjectDiş Mobilitesi
dc.subjectOrtodontik Aygıtlar
dc.subjectOrtodontik Braketler
dc.subjectDentistryen_US
dc.subjectSürtünme Katsayısı
dc.subjectDental Occlusionen_US
dc.subjectTooth Movementen_US
dc.subjectTooth Mobilityen_US
dc.subjectOrthodontic Appliancesen_US
dc.subjectOrthodontic Bracketsen_US
dc.subjectFriction Coefficienten_US
dc.subject.otherTEZ DOK Ö99f 2010en_US
dc.titleFarklı Braket Sistemlerinde Meydana Gelen Sürtünme Kuvvetlerinin Diş Hareketine Etkilerinin İncelenmesi
dc.titleAn Investigation on the Effects of Friction Resistance of Different Bracket Systems on the Tooth Movementen_US
dc.typeDoctoral Thesisen_US
dspace.entity.typePublication

Files