Publication:
Evaluation of Left Atrial Electromechanical Delay and Left Atrial Phasic Functions in Patients Undergoing Treatment With Cardiotoxic Chemotherapeutic Agents

dc.authorscopusid57218872312
dc.authorscopusid59051132500
dc.authorwosidAkcay, Murat/A-7829-2018
dc.authorwosidKertmen, Ömer/Gvu-6655-2022
dc.contributor.authorKertmen, Omer
dc.contributor.authorAkcay, Murat
dc.contributor.authorIDKertmen, Ömer/0000-0002-9951-2617
dc.contributor.authorIDAkcay, Murat/0000-0002-4610-8514
dc.date.accessioned2025-12-11T01:13:23Z
dc.date.issued2024
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Kertmen, Omer] Amasya Univ, Sabuncuoglu Serefeddin Training & Res Hosp, Dept Cardiol, TR-05100 Amasya, Turkiye; [Akcay, Murat] Ondokuz Mayis Univ, Fac Med, Dept Cardiol, TR-55270 Samsun, Turkiyeen_US
dc.descriptionKertmen, Ömer/0000-0002-9951-2617; Akcay, Murat/0000-0002-4610-8514;en_US
dc.description.abstractBackground: The aim of this study is to evaluate atrial involvement by comparing pre- and post-chemotherapy left atrial mechanical and electromechanical parameters in patients treated with cardiotoxic chemotherapeutic agents. Methods: We designed our study as a prospective cohort study. Sixty-eight female patients between the ages of 18 and 50, scheduled for treatment with cardiotoxic chemotherapeutic agents, were included in our study. Atrial mechanical functions and electromechanical parameters were examined and compared with basic echocardiographic parameters before and after chemotherapy. Results: The mean age of the patients was 41.6 +/- 7.9 years. After chemotherapy, lateral PA, septal PA, and tricuspid PA durations showed a significant increase (p < 0.001), but there were no statistically significant changes in the left intra-atrial electromechanical delay, the right intra-atrial electromechanical delay, or the interatrial electromechanical delay values. Following treatment, LAVmax, LAVmin, and LApreA significantly increased (p < 0.001). Additionally, the left atrial passive and active emptying volumes increased (p < 0.001), while the reservoir and pump (active emptying) functions decreased (with p-values of 0.03 and 0.01, respectively). The passive emptying function, however, showed no significant change (p = 0.65). Decreases in LVEF were observed, while LVEDD, LVESD, IVS, PW, and LA diameters increased (p-value of 0.02 for IVS and <0.001 for the others). Conclusions: Significant impairment of atrial mechanical functions and electromechanical parameters was observed after treatment with cardiotoxic chemotherapeutic agents. This suggests an elevated likelihood of atrial arrhythmia linked to the use of cardiotoxic chemotherapeutic agents.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.3390/medicina60091516
dc.identifier.issn1010-660X
dc.identifier.issn1648-9144
dc.identifier.issue9en_US
dc.identifier.pmid39336557
dc.identifier.scopus2-s2.0-85205106171
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.3390/medicina60091516
dc.identifier.urihttps://hdl.handle.net/20.500.12712/42105
dc.identifier.volume60en_US
dc.identifier.wosWOS:001326231000001
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.ispartofMedicina-Lithuaniaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCanceren_US
dc.subjectChemotherapyen_US
dc.subjectCardiotoxicityen_US
dc.subjectLeft Atrial Mechanical Functionsen_US
dc.subjectAtrial Electromechanical Delayen_US
dc.titleEvaluation of Left Atrial Electromechanical Delay and Left Atrial Phasic Functions in Patients Undergoing Treatment With Cardiotoxic Chemotherapeutic Agentsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files