Publication: A Micro-Sized PVC Membrane Li+-Selective Electrode Without Internal Filling Solution and Its Medical Applications
| dc.authorscopusid | 25921912000 | |
| dc.authorscopusid | 6701763136 | |
| dc.authorscopusid | 6603596907 | |
| dc.authorscopusid | 25923123100 | |
| dc.contributor.author | Coldur, F. | |
| dc.contributor.author | Andaç, M. | |
| dc.contributor.author | Işıldak, I. | |
| dc.contributor.author | Saka, T. | |
| dc.date.accessioned | 2020-06-21T15:07:10Z | |
| dc.date.available | 2020-06-21T15:07:10Z | |
| dc.date.issued | 2009 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Coldur] Fatih, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Işıldak] İbrahim, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Saka] T., Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey | en_US |
| dc.description.abstract | A micro-sized polyvinyl chloride (PVC) membrane Li+-selective electrode without inner filling solution was constructed. The emf measurements were made by using a micro-sized solid silver/silver chloride reference electrode. The potentiometric response characteristics of the electrode were examined under steady-state conditions. The developed electrode showed high selectivity for lithium with respect to common alkali and alkaline-earth metal cations. The working concentration range of the electrode was 1.0 × 10-1 to 6.0 × 10-5 mol L-1 with a slope of 53.6 mV decade-1, and pH working range was found to be 6-10. The electrode had a very short response time (<10 s) and good reproducibility. There was no significant change in the slope of the concentration-potential curve during the usage period of 10 weeks. The developed electrode was utilized for the determination of lithium contents of human blood serum samples and pharmaceutical formulations in steady-state conditions. The obtained potentiometric results for both serum samples and pharmaceutical formulations are in good agreement with atomic emission spectrophotometry (AES) results at the 95% confidence level. © 2008 Elsevier B.V. All rights reserved. | en_US |
| dc.identifier.doi | 10.1016/j.jelechem.2008.10.029 | |
| dc.identifier.endpage | 35 | en_US |
| dc.identifier.issn | 1572-6657 | |
| dc.identifier.scopus | 2-s2.0-58749084281 | |
| dc.identifier.scopusquality | Q2 | |
| dc.identifier.startpage | 30 | en_US |
| dc.identifier.uri | https://doi.org/10.1016/j.jelechem.2008.10.029 | |
| dc.identifier.volume | 626 | en_US |
| dc.identifier.wos | WOS:000263763500005 | |
| dc.identifier.wosquality | Q1 | |
| dc.language.iso | en | en_US |
| dc.publisher | Elsevier | en_US |
| dc.relation.ispartof | Journal of Electroanalytical Chemistry | en_US |
| dc.relation.journal | Journal of Electroanalytical Chemistry | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Blood Serum Analysis | en_US |
| dc.subject | Li+-Selective Electrode Without Inner Reference Solution | en_US |
| dc.subject | Pharmaceutical Formulations | en_US |
| dc.subject | Potentiometric Analysis | en_US |
| dc.subject | Solid-State Contact | en_US |
| dc.title | A Micro-Sized PVC Membrane Li+-Selective Electrode Without Internal Filling Solution and Its Medical Applications | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |