Publication:
A Micro-Sized PVC Membrane Li+-Selective Electrode Without Internal Filling Solution and Its Medical Applications

dc.authorscopusid25921912000
dc.authorscopusid6701763136
dc.authorscopusid6603596907
dc.authorscopusid25923123100
dc.contributor.authorColdur, F.
dc.contributor.authorAndaç, M.
dc.contributor.authorIşıldak, I.
dc.contributor.authorSaka, T.
dc.date.accessioned2020-06-21T15:07:10Z
dc.date.available2020-06-21T15:07:10Z
dc.date.issued2009
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Coldur] Fatih, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Işıldak] İbrahim, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Saka] T., Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA micro-sized polyvinyl chloride (PVC) membrane Li+-selective electrode without inner filling solution was constructed. The emf measurements were made by using a micro-sized solid silver/silver chloride reference electrode. The potentiometric response characteristics of the electrode were examined under steady-state conditions. The developed electrode showed high selectivity for lithium with respect to common alkali and alkaline-earth metal cations. The working concentration range of the electrode was 1.0 × 10-1 to 6.0 × 10-5 mol L-1 with a slope of 53.6 mV decade-1, and pH working range was found to be 6-10. The electrode had a very short response time (<10 s) and good reproducibility. There was no significant change in the slope of the concentration-potential curve during the usage period of 10 weeks. The developed electrode was utilized for the determination of lithium contents of human blood serum samples and pharmaceutical formulations in steady-state conditions. The obtained potentiometric results for both serum samples and pharmaceutical formulations are in good agreement with atomic emission spectrophotometry (AES) results at the 95% confidence level. © 2008 Elsevier B.V. All rights reserved.en_US
dc.identifier.doi10.1016/j.jelechem.2008.10.029
dc.identifier.endpage35en_US
dc.identifier.issn1572-6657
dc.identifier.scopus2-s2.0-58749084281
dc.identifier.scopusqualityQ2
dc.identifier.startpage30en_US
dc.identifier.urihttps://doi.org/10.1016/j.jelechem.2008.10.029
dc.identifier.volume626en_US
dc.identifier.wosWOS:000263763500005
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofJournal of Electroanalytical Chemistryen_US
dc.relation.journalJournal of Electroanalytical Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBlood Serum Analysisen_US
dc.subjectLi+-Selective Electrode Without Inner Reference Solutionen_US
dc.subjectPharmaceutical Formulationsen_US
dc.subjectPotentiometric Analysisen_US
dc.subjectSolid-State Contacten_US
dc.titleA Micro-Sized PVC Membrane Li+-Selective Electrode Without Internal Filling Solution and Its Medical Applicationsen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files