Publication:
Compatibility of True and Virtual Unenhanced Attenuation in Rapid kV-Switching Dual Energy CT

dc.authorscopusid56060485500
dc.contributor.authorCamlıdag, İ.
dc.date.accessioned2020-06-21T12:18:21Z
dc.date.available2020-06-21T12:18:21Z
dc.date.issued2020
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Camlıdag] İlkay, Department of Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractPURPOSE We aimed to evaluate whether virtual unenhanced images generated from nephrographic phase on rapid kV-switching dual energy computed tomography (rsDECT) can replace true unenhanced images by comparing attenuation values of various intraabdominal structures. METHODS In this retrospective study, 142 patients had unenhanced and nephrographic phase DECT images. Attenuation values of the aorta, liver, spleen, pancreas, bilateral renal parenchyma, inferior vena cava, gallbladder and paraspinal muscle on true and virtual unenhanced images were recorded. Frequency of organs that had more than 10 and 20 HU of attenuation difference were also calculated. RESULTS A total of 1224 regions of interest were sampled. No statistically significant differences were found between true and virtual unenhanced attenuation of the aorta, spleen and pancreas. The other structures had significant differences (P < 0.001). Correlation between measurements were weak to moderate (r, 0.17–0.72). Of the organs, 20% had more than 10 HU difference and 5% had more than 20 HU difference between true and virtual unenhanced images. CONCLUSION rsDECT-based virtual unenhanced images do not seem to be an ideal surrogate for true unenhanced images. © Turkish Society of Radiology 2020.en_US
dc.identifier.doi10.5152/dir.2019.19345
dc.identifier.endpage100en_US
dc.identifier.issn1305-3825
dc.identifier.issn1305-3612
dc.identifier.issue2en_US
dc.identifier.pmid32116219
dc.identifier.scopus2-s2.0-85080840858
dc.identifier.scopusqualityQ2
dc.identifier.startpage95en_US
dc.identifier.trdizinid365627
dc.identifier.urihttps://doi.org/10.5152/dir.2019.19345
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/365627/compatibility-of-true-and-virtual-unenhanced-attenuation-in-rapid-kv-switching-dual-energy-ct
dc.identifier.volume26en_US
dc.identifier.wosWOS:000518142400004
dc.identifier.wosqualityQ3
dc.institutionauthorCamlıdag, İ.
dc.language.isoenen_US
dc.publisherAVES 105/9 Buyukdere Cad Mecidiyekoy,Sisli, Istanbul 34394en_US
dc.relation.ispartofDiagnostic and Interventional Radiologyen_US
dc.relation.journalDiagnostic and Interventional Radiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleCompatibility of True and Virtual Unenhanced Attenuation in Rapid kV-Switching Dual Energy CTen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files