Publication:
Halojen ve Led İle Polimerize Edilmiş Bulk Fill Kompozit Rezinlerin Dönüşüm Derecesi ve Mikrosertlik Değerlerinin Karşılaştırmalı Olarak İncelenmesi

dc.contributor.advisorErtaş, Ertan
dc.contributor.authorKütük, Merve
dc.date.accessioned2020-07-21T21:15:45Z
dc.date.available2020-07-21T21:15:45Z
dc.date.issued2018
dc.departmentOMÜ, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Anabilim Dalıen_US
dc.departmentDiş Hekimliği Fakültesi / Restoratif Diş Tedavisi Ana Bilim Dalı
dc.descriptionTez (dişte uzmanlık) -- Ondokuz Mayıs Üniversitesi, 2018en_US
dc.descriptionLibra Kayıt No: 128480en_US
dc.description.abstractAmaç: Bu çalışmanın amacı; yeni nesil tek tabaka halinde uygulanabilen bulk fill kompozit rezinlerin QTH ve LED ışık cihazları ile polimerize edilerek dönüşüm değerlerinin ve mikrosertlik düzeylerinin karşılaştırılmasıdır. Materyal ve Metot: Çalışmamızda 6 farklı bulk fill kompozit rezin; SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (VOCO), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), Filtek Bulk Flowable (3M ESPE) ve kontrol grubu olarak 1 adet mikrohibrit tipte Filtek Z250 (3M ESPE) kullanılımştır. Kompozit rezinlerden 7 mm çapında 2 ve 4 mm kalınlığında disk şeklinde örnekler hazırlanarak, LED (Elipar S10, 3M ESPE) ve QTH (Hilux, Benlioğlu) ışık cihazları kullanılarak polimerize edilmiştir. Örneklerin 24 saat 37 °C'de bekletilmesinin ardından FTIR-ATR (Perkin Elmer Spectrum Two) ile dönüşüm yüzdeleri belirlenmiş ve ardından Knoop sertlik cihazı (Buehler MMT-3 Digital microhardness tester; Lake Bluff, IL, USA) ile sertlik ölçümleri yapılmıştır. Verilerin istatistiksel değerlendirmesinde çok yönlü Varyans Analizi ve Tukey çoklu karşılaştırma testi uygulanmıştır (p<0.05). Bulgular: Tüm kompozit grupları içerisinde en yüksek dönüşüm derecesini 2 mm'de LED ışık cihazı ile Filtek Z250 gösterirken, en düşük değeri 4 mm'de QTH ile Beautifil Bulk Flowable göstermiştir. 2 mm LED ile polimerize edilmiş X-tra Fil alt ve üst yüzey sertlik ortalamalarında en yüksek değeri gösterirken, 4 mm'de QTH ile polimerize edilmiş Filtek Bulk Flowable üst yüzey, Filtek Z250 ise alt yüzey sertlik ortalamalarında en düşük değeri göstermişlerdir. Sonuç: Çalışmada kullanılan kompozit rezinlerin dönüşüm dereceleri ve sertlikleri örneklerin kalınlığından ve ışık cihazlarından etkilenmiştir. Bulk Fil kompozit rezinlerin dönüşüm dereceleri ile sertlik değerleri arasında ilişki olmadığı gösterilmiştir. Bütün kalınlıklarda LED ile polimerize edilen örneklerin dönüşüm ve mikrosertlik değerleri QTH'tan yüksek çıkmıştır.
dc.description.abstractPurpose: The purpose of this study is to compare the conversion values and microhardness levels of new generation bulk fill composite resins that can be applied in one layer by polymerizing them with QTH and LED light devices. Material and Method: 6 different bulk fill composite resins SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (VOCO), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), Filtek Bulk Flowable (3M ESPE) and 1 microhybrid type Filtek Z250 (3M ESPE) as the control group were used in our study. Samples with a diameter of 7 mm and thickness of 2 and 4 mm in the form of discs were prepared from the composite resins and they were polymerized by using LED (Elipar S10, 3M ESPE) and QTH (Hilux, Benlioğlu) light devices. After the samples were kept for 24 hours at 37 °C, their conversion degree were found with FTIR-ATR (Perkin Elmer Spectrum Two) and their hardness measurements were made with Knoop hardness device (Buehler MMT-3 Digital microhardness tester; Lake Bluff, IL, USA). In the statistical assessment of the data, Multi-Way analysis of variance and Tukey multi comparison test were applied (p<0.05). Results: Of all the composite groups, while Filtek Z250 showed the highest conversion degree with LED light device at 2 mm, Beautifil Bulk Flowable showed the lowest conversion degree with QTH at 4 mm. While X-tra Fil polymerized with 2 mm LED showed the highest degree in bottom and top surface hardness averages, Filtek Bulk Flowable polymerized with QTH at 4 mm showed the lowest degree in top surface hardness averages and Filtek Z250 polymerized with QTH at 4 mm showed the lowest degree in bottom surface hardness averages. Conclusion: Conversion degrees and hardness of composite resins used in the study were influenced by the thickness of the samples and by the light devices. No association was found between the conversion degrees and hardness values of bulk fill composite resins. In all thicknesses, conversion and microhardness values of samples polymerized with LED were found to be higher than those of QTH.en_US
dc.formatIX, 91 y. : tablo ; 30 sm.en_US
dc.identifier.endpage102
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=T1mWGp9MngYYkCSgiJvtVgUKoBkRf8Eg7_GgaZjS_YycZ9i61l6pq1WreQJb9tC5
dc.identifier.urihttp://libra.omu.edu.tr/tezler/128480.pdf
dc.identifier.yoktezid549717
dc.language.isotren_US
dc.language.isotr
dc.publisherOndokuz Mayıs Üniversitesi, Diş Hekimliği Fakültesien_US
dc.relation.publicationcategoryTezen_US]
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliği
dc.subjectHalojenler
dc.subjectIşık Yayan Diyot
dc.subjectDentistryen_US
dc.subjectKompozit Reçineler
dc.subjectHalogensen_US
dc.subjectMikrosertlik
dc.subjectLight Emitting Diodeen_US
dc.subjectComposite Resinsen_US
dc.subjectMicrohardnessen_US
dc.subject.otherTEZ DİŞ K97h 2018en_US
dc.titleHalojen ve Led İle Polimerize Edilmiş Bulk Fill Kompozit Rezinlerin Dönüşüm Derecesi ve Mikrosertlik Değerlerinin Karşılaştırmalı Olarak İncelenmesi
dc.titleComparative Analysis of Conversion Degrees and Microhardness Values of Bulk Fill Composite Resins Polymerized With Different Light Devicesen_US
dc.typeSpecialist Thesisen_US
dspace.entity.typePublication

Files