Publication:
The Effect of Curing Lights and Modes on Dentin Bond Strength of Bulk-Fill Composites Applied in Different Thickness

dc.authorscopusid57199227791
dc.authorscopusid35310125300
dc.authorscopusid57210590926
dc.authorscopusid57210591008
dc.authorscopusid57210590884
dc.contributor.authorMisilli, T.
dc.contributor.authorGönülol, N.
dc.contributor.authorCabadag˘, Ö.G.
dc.contributor.authorAlmasifar, L.
dc.contributor.authorMisilli, U.
dc.date.accessioned2020-06-21T12:26:19Z
dc.date.available2020-06-21T12:26:19Z
dc.date.issued2019
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Misilli] Tuǧba, Department of Restorative Dentistry, Çanakkale Onsekiz Mart Üniversitesi, Canakkale, Canakkale, Turkey; [Gönülol] Nihan, Department of Restorative Dentistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Cabadag˘] Özge Gizem, Department of Restorative Dentistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Almasifar] Lena, Department of Restorative Dentistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Misilli] Umut, Çanakkale Oral and Dental Health Center, Canakkale, Erzurum, Turkeyen_US
dc.description.abstractTo investigate shear bond strength (SBS) to dentin of a conventional and three bulk-fill composites applied in different increment thickness and cured by mono- and multi-wave LED LCUs. Two hundred and fifty-two extracted sound human molars were prepared for SBS test. The teeth were divided into four groups according to the resin composites used. Conventional composite: Tetric N-Ceram (control); high-viscosity bulk-fills: Tetric N-Ceram Bulk Fill, X-tra Fil, and SonicFill. Each group was subdivided (n = 7) according to increment thickness (2, 4, and 6 mm) and cured by standard mode of a mono-wave LED or two different modes (standard and xtra power) of a multi-wave LED. The failure mode was stereomicroscopically determined at 40× magnification. Data were analyzed using Three-way ANOVA and further comparisons were assessed by Bonferroni’s multiple comparison test. There were no significant differences within X-tra fil and Tetric N-Ceram Bulk Fill groups for any of the variables (p > 0.05). A significant decrease in SBS values with increase of layer thickness was observed for SonicFill and control groups. Also, curing mode had a significant effect on both composites at 6 mm thickness and standard mode of multi-wave LED caused the highest SBS value (p ˂ 0.05). Adhesive failure was the most common fracture pattern especially at 6 mm thickness applications. Based on the results of this study, the bulk-fill composites can be safely applied in one-step with 4 mm increments, although the examined composites performed better at 2 mm thickness. The performance of the composites at 6 mm increment may show differences related to the curing lights and modes. © 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.en_US
dc.identifier.doi10.1080/01694243.2019.1640174
dc.identifier.endpage2291en_US
dc.identifier.issn0169-4243
dc.identifier.issn1568-5616
dc.identifier.issue20en_US
dc.identifier.scopus2-s2.0-85071056294
dc.identifier.scopusqualityQ2
dc.identifier.startpage2281en_US
dc.identifier.urihttps://doi.org/10.1080/01694243.2019.1640174
dc.identifier.volume33en_US
dc.identifier.wosWOS:000478275200001
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherTaylor and Francis Ltd. michael.wagreich@univie.ac.aten_US
dc.relation.ispartofJournal of Adhesion Science and Technologyen_US
dc.relation.journalJournal of Adhesion Science and Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBulk-Fill Compositesen_US
dc.subjectIncrement Thicknessen_US
dc.subjectLED Curing Lightsen_US
dc.subjectShear Bond Strengthen_US
dc.titleThe Effect of Curing Lights and Modes on Dentin Bond Strength of Bulk-Fill Composites Applied in Different Thicknessen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files