Publication:
A Simple Flow-Injection Spectrofluorimetric Method for the Determination of Mercury

dc.authorscopusid6701763136
dc.authorscopusid55984370700
dc.authorscopusid6507415687
dc.authorscopusid6603596907
dc.contributor.authorAndaç, M.
dc.contributor.authorAsan, A.
dc.contributor.authorTinkiliç, N.
dc.contributor.authorIşıldak, I.
dc.date.accessioned2020-06-21T15:19:39Z
dc.date.available2020-06-21T15:19:39Z
dc.date.issued2007
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Andaç] Müberra, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Asan] Adem, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Tinkiliç] Nihat, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Işıldak] İbrahim, Department of Chemistry, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractA highly sensitive flow-injection spectrofluorimetric method is presented for the rapid and simple determination of Hg (II) in environmental and pharmaceutical samples. Murexide (ammonium purpurate) was used as the fluorescence reagent in the carrier stream. An emission peak of murexide, which is decreased linearly by addition of Hg (II), occurs at 435 nm in aqueous solution with excitation at 335 nm. A linear calibration was obtained for 5-200 ng ml -1 Hg (II) with the relative standard deviation 2.5% (n∈=∈5) for a 20 μl injection volume Hg (II). The limit of the detection was 1 ng ml -1 and the sampling rate was 80 h -1. No significant interference was found by the ions commonly found in the most environmental samples. The proposed method was successfully applied for the determination of trace mercury in real samples and the validation of the proposed methodology is provided. © Springer Science+Business Media, LLC 2007.en_US
dc.identifier.doi10.1007/s10895-007-0182-4
dc.identifier.endpage405en_US
dc.identifier.issn1053-0509
dc.identifier.issn1573-4994
dc.identifier.issue4en_US
dc.identifier.pmid17457665
dc.identifier.scopus2-s2.0-34547361292
dc.identifier.scopusqualityQ3
dc.identifier.startpage401en_US
dc.identifier.urihttps://doi.org/10.1007/s10895-007-0182-4
dc.identifier.volume17en_US
dc.identifier.wosWOS:000248225600008
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherSpringer/Plenum Publishersen_US
dc.relation.ispartofJournal of Fluorescenceen_US
dc.relation.journalJournal of Fluorescenceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFlow-Injection Analysisen_US
dc.subjectFluorimetric Determinationen_US
dc.subjectMercury (II)en_US
dc.subjectMurexideen_US
dc.titleA Simple Flow-Injection Spectrofluorimetric Method for the Determination of Mercuryen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files