Publication:
Kappa-Free Light Chain as a Practical Alternative to Oligoclonal Bands in the Diagnosis of Multiple Sclerosis

dc.authorscopusid35095964200
dc.authorscopusid58798524600
dc.authorscopusid37666211300
dc.authorscopusid56042671700
dc.authorscopusid55635279900
dc.authorscopusid57193201285
dc.authorscopusid57193201285
dc.authorwosidArslan, Gökhan/A-7268-2017
dc.authorwosidUzunköprü, Cihat/W-4303-2017
dc.authorwosidGur Vural, Demet/Jgn-6160-2023
dc.contributor.authorBeckmann, Yesim
dc.contributor.authorDuztas, Dilan
dc.contributor.authorUzunkopru, Cihat
dc.contributor.authorSen, Sedat
dc.contributor.authorArslan, Gokhan
dc.contributor.authorVural, Demet Gur
dc.contributor.authorTerzi, Murat
dc.date.accessioned2025-12-11T00:46:44Z
dc.date.issued2025
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Beckmann, Yesim; Duztas, Dilan; Uzunkopru, Cihat] Izmir Katip Celebi Univ, Fac Med, Dept Neurol, Izmir, Turkiye; [Sen, Sedat; Terzi, Murat] Ondokuz Mayis Univ, Fac Med, Dept Neurol, Samsun, Turkiye; [Arslan, Gokhan] Ondokuz Mayis Univ, Fac Med, Dept Physiol, Samsun, Turkiye; [Vural, Demet Gur] Ondokuz Mayis Univ, Fac Med, Dept Med Microbiol, Samsun, Turkiyeen_US
dc.description.abstractObjectives: Kappa free light chains (x-FLC) have emerged as a reliable biomarker for diagnosing multiple sclerosis (MS). Compared to oligoclonal band (OCB) measurement, x-FLC presents distinct advantages, including enhanced accessibility in clinical practice. This study evaluates x-FLC index values in MS patients and explores its potential as a practical alternative to the OCB test. Methods: Cerebrospinal fluid (CSF) and serum x-FLC concentrations were quantified using an immunonephelometry analyzer, while OCB analysis was performed via agarose isoelectric focusing combined with immunoblotting. The cut-off values were set at >= 0.7 for the CSF IgG index and >= 6.6 for the x-FLC index, with values exceeding these thresholds considered positive. x-FLC index values were compared between OCB-negative and OCB-positive patients, between patients with negative and positive CSF IgG index, and across different OCB types. Results: OCB positivity was detected in 82.7 % of patients, whereas a positive x-FLC index was observed in 91.7 %. The IgG index was positive in 51.9 % and negative in 48.1 %. Among patients with a negative IgG index, 84.3 % exhibited a positive x-FLC index. Additionally, CSF x-FLC values were significantly higher in patients with a positive IgG index compared to those with a negative IgG index. On the other hand, patients with type 2 (+) OCBs had higher x-FLC index values than those with negative OCBs. Conclusions: The x-FLC index may serve as a valuable tool for identifying OCB-negative patients with a high likelihood of MS, offering a practical and accessible alternative for diagnostic evaluation.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1016/j.msard.2025.106377
dc.identifier.issn2211-0348
dc.identifier.issn2211-0356
dc.identifier.pmid40086224
dc.identifier.scopus2-s2.0-105000032339
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.1016/j.msard.2025.106377
dc.identifier.urihttps://hdl.handle.net/20.500.12712/39150
dc.identifier.volume97en_US
dc.identifier.wosWOS:001452488400001
dc.identifier.wosqualityQ2
dc.language.isoenen_US
dc.publisherElsevier Science Ltden_US
dc.relation.ispartofMultiple Sclerosis and Related Disordersen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMultiple Sclerosisen_US
dc.subjectKappa Free Light Chainsen_US
dc.subjectKappa Free Light Chain Indexen_US
dc.subjectOligoclonal Banden_US
dc.subjectIgG Indexen_US
dc.titleKappa-Free Light Chain as a Practical Alternative to Oligoclonal Bands in the Diagnosis of Multiple Sclerosisen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files