Publication:
The Electrocardiogram of the Conscious Chinese Goose (Anser Cygnoides)

dc.authorscopusid59102397900
dc.authorscopusid6506261292
dc.contributor.authorKaya, M.
dc.contributor.authorÇenesiz, M.
dc.date.accessioned2020-06-21T13:07:09Z
dc.date.available2020-06-21T13:07:09Z
dc.date.issued2018
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-temp[Kaya] Mehmet, Department of Physiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Çenesiz] Metin, Department of Physiology, Ondokuz Mayis Üniversitesi, Samsun, Turkeyen_US
dc.description.abstractThis study was carried out on 24 healthy adult Chinese goose (Anser cygnoides) to determine normal electrocardiographic values and patterns in standard bipolar and augmented bipolar limb leads. The study between males and females was also performed to investigate changes in the electrocardiographic patterns related to sex. A regular sinus rhythm was observed in all birds. There was no significant difference between male and female geese except for PR interval, therefore, all data was pooled. All waves in lead I had very low amplitude or almost isoelectric. The P waves, in other leads, were mainly positive in lead II, III and aVF, negative in lead aVR and biphasic in lead aVL. The all waveforms of the QRS complexes (approx.-0.90 mV and 0.03 seconds in lead II) were rS in lead II, III and aVF, and qR in lead aVR and aVL. The T waves (approx. 0.31 mV and 0.06 seconds in lead II) were totally positive in lead II, III and aVF, and negative in aVR and aVL. The majority of birds showed a ST slurring and slightly elevated ST segment in lead II. Heart rates were 142 ± 25 (Mean ± SD) beats per minute and mean electrical axes were-90.88±4.57° in geese. This study provides electrocardiographic data for Chinese goose, which can be used for clinical purposes. © 2018 Chulalongkorn University Printing House. All rights reserved.en_US
dc.identifier.doi10.56808/2985-1130.2937
dc.identifier.endpage492en_US
dc.identifier.issn0125-6491
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-85055142106
dc.identifier.scopusqualityQ3
dc.identifier.startpage487en_US
dc.identifier.urihttps://doi.org/10.56808/2985-1130.2937
dc.identifier.urihttps://hdl.handle.net/20.500.12712/11458
dc.identifier.volume48en_US
dc.identifier.wosWOS:000448683300019
dc.identifier.wosqualityQ4
dc.language.isoenen_US
dc.publisherChulalongkorn University Printing Houseen_US
dc.relation.ispartofThai Journal of Veterinary Medicineen_US
dc.relation.journalThai Journal of Veterinary Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAnser Cygnoidesen_US
dc.subjectChinese Gooseen_US
dc.subjectElectrocardiographyen_US
dc.subjectHeart Rateen_US
dc.subjectMean Electrical Axisen_US
dc.titleThe Electrocardiogram of the Conscious Chinese Goose (Anser Cygnoides)en_US
dc.typeArticleen_US
dspace.entity.typePublication

Files