Publication:
Determination of Sulfonated Naphthalene Formaldehyde Superplasticizer in Cement - A New Spectrofluorometric Method and Assessment of the UV Method

dc.authorscopusid58717985000
dc.authorscopusid6603967476
dc.authorscopusid7005377398
dc.authorwosidYilmaz, Veysel/L-7238-2018
dc.authorwosidYilmaz, Veysel Turan/L-7238-2018
dc.contributor.authorYILMAZ, VT
dc.contributor.authorKINDNESS, A
dc.contributor.authorGLASSER, FP
dc.contributor.authorIDKindness, Anew/0000-0001-8673-5726
dc.contributor.authorIDYilmaz, Veysel Turan/0000-0002-2849-3332
dc.date.accessioned2020-06-21T09:20:14Z
dc.date.available2020-06-21T09:20:14Z
dc.date.issued1992
dc.departmentOndokuz Mayıs Üniversitesien_US
dc.department-tempUNIV ABERDEEN,DEPT CHEM,ABERDEEN AB9 2UE,SCOTLANDen_US
dc.descriptionKindness, Anew/0000-0001-8673-5726; Yilmaz, Veysel Turan/0000-0002-2849-3332en_US
dc.description.abstractThe quantitative determination of SNF in the aqueous phase of fresh cement-water systems have been investigated by UV spectrophotometry and spectrofluorimetry. The conventional UV method gives a spectrum with three-lambda-max values at ca. 227, 292 and 328nm, which may be used for analysis. However, different lambda-max values produce rather different results for the same species of SNF in the aqueous phase of fresh cement mixes although a11 follow the same trends. The SNF concentrations in solutions measured at ca. 227nm are significantly higher than those obtained at 292nm and 328nm. Alternatively, a method based on spectrofluorimetry may be used for SNF analysis. The results obtained using this method are in very good agreement with those produced by the UV method at 227nm, suggesting that true SNF concentrations in fresh or hardened cement pastes can be measured either by spectrofluorimetry or by UV spectrophotometry at 227nm.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.doi10.1016/0008-8846(92)90018-Q
dc.identifier.endpage670en_US
dc.identifier.issn0008-8846
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-0026896708
dc.identifier.scopusqualityQ1
dc.identifier.startpage663en_US
dc.identifier.urihttps://doi.org/10.1016/0008-8846(92)90018-Q
dc.identifier.volume22en_US
dc.identifier.wosWOS:A1992JA87800018
dc.identifier.wosqualityQ1
dc.language.isoenen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofCement and Concrete Researchen_US
dc.relation.journalCement and Concrete Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleDetermination of Sulfonated Naphthalene Formaldehyde Superplasticizer in Cement - A New Spectrofluorometric Method and Assessment of the UV Methoden_US
dc.typeArticleen_US
dspace.entity.typePublication

Files