dc.department-temp[Bodrumlu] Emre H., Department of Operative Dentistry and Endodontics, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Sumer] Ayse Pinar, Department of Oral Diagnosis and Radiology, Ondokuz Mayis Üniversitesi, Samsun, Turkey; [Güngör] Kahraman, Department of Oral Diagnosis and Radiology, Gazi Üniversitesi, Ankara, Ankara, Turkeyen_US
dc.description.abstractObjective: The purpose of this study was to evaluate the radiopacity of a new root canal sealer, Epiphany, relative to 3 other root canal sealing materials, AH 26, Sealapex, and Ketac-Endo. Study design: Radiographs were taken of 1-mm-thick specimens of 4 root canal sealers and dentine slides, as well as a range of aluminum thicknesses, by using a step-wedge. The radiographic density of each specimen was measured and correlated with the equivalent thickness of aluminum. Results: All sealers were found to be more radiopaque than dentine (1.05 ± 0.2-mm aluminum) and to possess radiopacity of greater than 3-mm aluminum. The radiopacity values reported in this study were 11.27 ± 0.18-mm, 10.88 ± 0.16-mm, 10.35 ± 0.15-mm, and 9.78 ± 0.21-mm aluminum for Sealapex, Ketac-Endo, Epiphany, and AH 26, respectively, which were significantly different from each other (P < .01). Conclusion: Radiopacity measurements for Epiphany, Ketac-Endo, Sealapex, and AH 26 exceeded the minimum standard for root canal sealers. Epiphany has higher radiopacity than dentine. Therefore, this sealer is suitable for endodontic usage in terms of radiographic assessment. © 2007 Mosby, Inc. All rights reserved.en_US
dc.identifier.doi10.1016/j.tripleo.2007.05.031
dc.identifier.endpagee61en_US
dc.identifier.issn1079-2104
dc.identifier.issue5en_US
dc.identifier.pmid17764983
dc.identifier.scopus2-s2.0-35348934224
dc.identifier.startpagee59en_US
dc.identifier.urihttps://doi.org/10.1016/j.tripleo.2007.05.031
dc.identifier.volume104en_US
dc.identifier.wosWOS:000250921700031
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodonticsen_US
dc.relation.journalOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleRadiopacity of a New Root Canal Sealer, Epiphanyen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files