Publication: Simultaneous Determination of Nickel(II), Copper(II), and Cobalt(II) in Environmental Samples at Trace Levels by Reversed-Phase High-Performance Liquid Chromatography Using Shiff Base Complexes
| dc.authorscopusid | 57189904200 | |
| dc.authorscopusid | 55984370700 | |
| dc.contributor.author | Konanc, M. Umut | |
| dc.contributor.author | Asan, Adem | |
| dc.date.accessioned | 2025-12-11T00:34:34Z | |
| dc.date.issued | 2025 | |
| dc.department | Ondokuz Mayıs Üniversitesi | en_US |
| dc.department-temp | [Konanc, M. Umut] Artvin Coruh Univ, Artvin Vocat Sch, Artvin, Turkiye; [Asan, Adem] Ondokuz Mayis Univ, Fac Sci, Dept Chem, Samsun, Turkiye | en_US |
| dc.description.abstract | A new method for the simultaneous determination of Ni(II), Cu(II), and Co(II) ions in environmental samples by reversed-phase liquid chromatography was developed. The developed method is based on the synthesis of the quadrivalent Schiff base 6,6'-((1E,1'E)-(ethane-1,2-diylbis(azaneylylidene))bis(methaneylylidene))bis(3-methoxyphenol) by the condensation reaction between 2-hydroxy-4-methoxybenzaldehyde and ethylenediamine. The resulting Schiff base was used as a chelating agent to convert the targeted ions into metal-ligand complexes within 1 min, which were extracted on an octadecylsilane (ODS) solid-phase extraction mini-column and then injected into a reversed-phase high-performance liquid chromatography system. Sufficient separation of the metal-ligand complexes was achieved on a GL Sciences Intersil ODS-3 column with a mobile phase composition of methanol-acetonitrile-water (30 : 30 : 40, v/v) within 6 min and detection by an ultraviolet detector at 254 nm. The limits of detection were found to be 0.45, 0.40, and 1.47 mu g/L for Co2+, Cu2+, and Ni2+, respectively. Recoveries from water samples ranged from 97.4 to 103.6%, with relative standard deviation values between 0.4 and 1.7%. While the targeted metal ions were not detected in a sample from the remote upstream area of the Kabaca Stream (Artvin, Turkey), concentrations were found to be 116.4 mu g/L for Cu2+ and 32.9 mu g/L for Ni2+ in a sample taken from the Kabaca Stream near the industrial area (Artvin, Turkey). Co2+ was below the limit of detection in both cases. In addition, the developed method was also validated using the inductively coupled plasma optical emission spectrometry technique. | en_US |
| dc.description.woscitationindex | Science Citation Index Expanded | |
| dc.identifier.doi | 10.1134/S1061934825700303 | |
| dc.identifier.endpage | 902 | en_US |
| dc.identifier.issn | 1061-9348 | |
| dc.identifier.issn | 1608-3199 | |
| dc.identifier.issue | 5 | en_US |
| dc.identifier.scopus | 2-s2.0-105008179475 | |
| dc.identifier.scopusquality | Q3 | |
| dc.identifier.startpage | 894 | en_US |
| dc.identifier.uri | https://doi.org/10.1134/S1061934825700303 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12712/37632 | |
| dc.identifier.volume | 80 | en_US |
| dc.identifier.wos | WOS:001510028400003 | |
| dc.identifier.wosquality | Q4 | |
| dc.language.iso | en | en_US |
| dc.publisher | Pleiades Publishing Ltd | en_US |
| dc.relation.ispartof | Journal of Analytical Chemistry | en_US |
| dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
| dc.rights | info:eu-repo/semantics/closedAccess | en_US |
| dc.subject | Trace Elements | en_US |
| dc.subject | Schiff Base | en_US |
| dc.subject | HPLC | en_US |
| dc.subject | Diode Array Detector | en_US |
| dc.subject | SPE | en_US |
| dc.title | Simultaneous Determination of Nickel(II), Copper(II), and Cobalt(II) in Environmental Samples at Trace Levels by Reversed-Phase High-Performance Liquid Chromatography Using Shiff Base Complexes | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |
