Publication:
Does Surgical Technique Influence Cataract Surgery Contamination?

dc.contributor.authorKoc, F
dc.contributor.authorAkcam, Z
dc.contributor.authorKuruoglu, S
dc.contributor.authorOge, I
dc.contributor.authorGunaydin, M
dc.date.accessioned2020-06-21T15:49:28Z
dc.date.available2020-06-21T15:49:28Z
dc.date.issued2001
dc.departmentOMÜen_US
dc.department-tempOndokuz Mayis Univ, Sch Med, Dept Ophthalmol, Samsun, Turkey -- Ondokuz Mayis Univ, Sch Med, Dept Microbiol, Samsun, Turkey --en_US
dc.description.abstractPURPOSE. To compare cataract surgery contamination rates in large-incision extracapsular cataract extraction (ECCE) and phacoemulsification (PE), we studied 65 cases prospectively. METHODS. Thirty-five cases were operated by large-incision ECCE (Group I) and 30 by PE (Group II). Conjunctival swab cultures were taken immediately before surgery and anterior chamber aspirate was taken for culture upon completion of surgery for each case. RESULTS. Anterior chamber cultures were positive in 22.8% of the cases in group I and 23% in Group II. Frequencies of contamination in each group were no different (x(2): 0.22, p>0.05). When the contaminations were evaluated in relation to operating time, prolongation of the operating time raised the contamination rate in Group I (p<0.05) but not in Group II (p>0.05). Silicone and PMMA intraocular lenses (IOL) were tested to see whether they had any additional risk of contamination. The frequencies of contaminated silicone IOL implanted cases (6/26) and contaminated PMMA IOL implanted cases (8/39) were similar (x(2): 0.36, p >0.05). CONCLUSIONS. Although the architecture of the incision and irrigation dynamics provided an advantage to the PE technique as the operating time became longer, routine PE was not superior to classical ECCE with respect to contamination when performed in the same circumstances. Prolonging the operating time raised the contamination rate in classical ECCE.en_US
dc.identifier.endpage36en_US
dc.identifier.issn1120-6721
dc.identifier.issn1724-6016
dc.identifier.issue1en_US
dc.identifier.pmid11284482
dc.identifier.startpage31en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12712/22238
dc.identifier.volume11en_US
dc.identifier.wosWOS:000167597900007
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.relation.journalEuropean Journal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectExtracapsular Cataract Extractionen_US
dc.subjectPhacoemulsificationen_US
dc.subjectContaminationen_US
dc.titleDoes Surgical Technique Influence Cataract Surgery Contamination?en_US
dc.typeArticleen_US
dspace.entity.typePublication